APC
APC APDU11450SW PDU Switched 34.6kW 400V 63A 42 Outlet 21x C13/C15/C19/C21
Switched rack PDU delivers 34.6 kW at 400 V with 42 combination outlets and remote outlet control
- TypePDUs & Line Conditioners
- Output Voltage240 V
- Output Connector(s)21 C13/C15/C19/C21 21C13/C15
- DimensionsWidth: 71.9 Inch Depth: 2.2 Inch Height: 3 Inch
- Switched outlets enable remote power cycling per socket
- 42 outlets in a 2.2 in wide 0U chassis maximise rack density
- 4-in-1 C13/C15/C19/C21 combo ports fit any IEC plug
- 6 kW three-phase capacity at 400 V / 63 A
- Metered input with NMC3 card supports EcoStruxure IT monitoring
Three-phase power for high-density racks
The APC NetShelter Rack PDU Advanced Gen 2 delivers 34.6 kW at 400 V or 43.5 kW at 415 V across 42 switched outlets. Each 4-in-1 outlet accepts C13, C15, C19 or C21 plugs, giving 21 C13/C15 and 21 C13/C15/C19/C21 combinations in a 2.2 in wide 0U vertical form factor. Remote on/off control and PDU-level metering let administrators manage power per outlet and receive overload alerts. The unit ships new with an IEC 60309 60 A 3P+N+PE input plug and a 9.84 ft cord.
Verify three-phase supply and outlet mix
Confirm the facility provides 400 V or 415 V three-phase power with a 63 A or 60 A service matching the IEC 60309 3P+N+PE connector. Ensure the rack can accommodate a 71.9 in tall vertical PDU and that the 2.2 in width fits the available 0U mounting space. Check that connected devices use IEC 60320 C13, C15, C19 or C21 plugs so they match the 42 colour-coded, breaker-labelled outlets. The PDU operates up to 60 C at full load, so verify rack airflow meets that temperature limit.
NMC3 and EcoStruxure IT integration
A hot-swappable NMC3 network management card provides web, SNMP and CLI access without powering down the PDU. Integration with EcoStruxure IT enables centralised monitoring, firmware updates and alerting across the infrastructure. The 9.84 ft input cord eases routing to the upstream power source, while the switched outlets and metering support remote reboot and capacity planning from the same management plane.
Highlights
- Switched outlets enable remote power cycling per socket
- 42 outlets in a 2.2 in wide 0U chassis maximise rack density
- 4-in-1 C13/C15/C19/C21 combo ports fit any IEC plug
- 6 kW three-phase capacity at 400 V / 63 A
- Metered input with NMC3 card supports EcoStruxure IT monitoring
Specifications
| Brand | APC |
|---|---|
| Series | NetShelter Rack |
| Model | APDU11450SW |
| Part Number | APDU11450SW |
| Type | PDUs & Line Conditioners |
| Output Voltage | 240 V |
| Output Connector(s) | 21 C13/C15/C19/C21 21C13/C15 |
| Dimensions | Width: 71.9 Inch Depth: 2.2 Inch Height: 3 Inch |
| Shipping weight | 15.47 kg |
| Package size | 2096 × 267 × 131 mm |
Questions about this item
What outlets are included on the APDU11450SW and do I need to buy any cables separately?
The unit provides 42 outlets — 21 combination C13/C15/C19/C21 and 21 C13/C15. It ships with a 9.84 ft IEC 60309 60 A 3P+N+PE input cord. Equipment power cables with matching IEC 60320 plugs must be supplied separately.
Should I choose the 400 V 63 A or 415 V 60 A rating for my three-phase supply?
The PDU delivers 34.6 kW at 400 V 63 A or 43.5 kW at 415 V 60 A. Select the rating that matches your facility’s nominal three-phase voltage and upstream breaker size.
What does the 34.6 kW figure mean when the PDU is installed in a rack?
At 400 V three-phase the PDU can continuously supply 34.6 kW across its 42 outlets while operating at up to 140 °F inlet temperature. The 0U vertical form factor (71.9 in tall, 2.2 in wide) fits standard racks without consuming rack units.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.