APC
APC APDU11250SW Switched PDU 11.5kW 3Phase 415V 20A 520P6 42 Outlet
Distributes 11.5 kW three-phase power at 415 V with 20 A input, 42 switched outlets and a 520P6 plug
- TypePDUs & Line Conditioners
- Remote Management ProtocolPower Distribution Unit
- Switched control enables remote outlet power cycling
- 5 kW three-phase capacity supports dense rack loads
- 415 V 20 A input matches industrial power infrastructure
- 42 outlets provide high-density power distribution
- 520P6 plug ensures secure three-phase connection
Switched NetShelter PDU for 3-phase 415V racks
This APC NetShelter switched PDU delivers 11.5 kW through a three-phase 415 V supply rated at 20 A. It provides 42 locking outlets fed by a 520P6 inlet for high-density power distribution in rack environments.
Suited for administrators needing per-outlet
Operators who require individual outlet switching and IP-based monitoring will benefit from the advanced management features. Facilities limited to single-phase 400 V at 16 A or lacking a 520P6 supply should consider alternative power distribution units.
11.5 kW three-phase capacity at 415 V 20 A
The unit’s 11.5 kW rating on a 415 V three-phase 20 A feed is the decisive specification; it determines whether the PDU matches the site’s electrical infrastructure and rack power budget.
Highlights
- Switched control enables remote outlet power cycling
- 5 kW three-phase capacity supports dense rack loads
- 415 V 20 A input matches industrial power infrastructure
- 42 outlets provide high-density power distribution
- 520P6 plug ensures secure three-phase connection
Specifications
| Brand | APC |
|---|---|
| Series | NetShelter |
| Model | APDU11250SW |
| Part Number | APDU11250SW |
| Type | PDUs & Line Conditioners |
| Remote Management Protocol | Power Distribution Unit |
| Shipping weight | 9.21 kg |
| Package size | 1727 × 216 × 127 mm |
Questions about this item
What rack enclosure does the APDU11250SW require for mounting?
The PDU is built for vertical installation in a NetShelter rack or any standard 42U enclosure that accepts zero-U accessories.
Will the 520P6 plug on this 20A 415V unit work with my existing 16A 400V three-phase supply?
The 520P6 connector is rated for 20A at 415V; a 16A 400V source uses a different pin arrangement so an adapter or rewired inlet is required.
How can I confirm the switched outlets are responding after configuration?
Use the web interface or SNMP to send an on/off command to a single outlet and verify the connected device powers up or down accordingly.