APC
APC APDU11151SM PDU 5.0kW 208V 30A L6-30P 40 Outlets Switched Metered-by-Outlet
Delivers 5.0 kW at 208 V through 40 switched, outlet-metered IEC outlets in a 0U vertical form factor
- TypePower Distribution Units
- Rack Size0U
- Output Connector(s)C13, C15, C19, and C21 in one outlet
- Switched outlets enable remote power cycling of each device
- Metered-by-outlet monitoring delivers per-outlet energy visibility
- 40 combination outlets fit in a 2.2 in wide vertical form factor
- NEMA L6-30P input supports 208 V 30 A single-phase supply
- Rated for continuous operation at 60 C ambient temperature
APC NetShelter Switched PDU
This APC NetShelter APDU11151SM is a 0U vertical power distribution unit rated at 5.0kW for 208V single-phase circuits. It delivers 40 outlets through a NEMA L6-30P input plug and a 9.84 ft cord. Switched, metered-by-outlet control lets administrators cycle power remotely and track consumption per device.
Replaces basic unmetered strips
It replaces rack strips that only pass power without visibility or remote control. The jump is worth it when you need outlet-level metering to detect overloads early or switched outlets to reboot hung servers without a site visit. Color-coded breakers simplify load balancing across the 30A feed.
Limited by 30A single-phase input
The L6-30P inlet caps total draw at 30A, so the 5.0kW rating cannot be exceeded even with 40 outlets populated. The 4-in-1 C13/C15/C19/C21 outlets accept mixed cord types, but each outlet shares the same branch circuit protection. Operating temperature is rated to 60 C at full load.
Highlights
- Switched outlets enable remote power cycling of each device
- Metered-by-outlet monitoring delivers per-outlet energy visibility
- 40 combination outlets fit in a 2.2 in wide vertical form factor
- NEMA L6-30P input supports 208 V 30 A single-phase supply
- Rated for continuous operation at 60 C ambient temperature
Specifications
| Brand | APC |
|---|---|
| Series | NetShelter Rack PDU |
| Model | APDU11151SM |
| Part Number | APDU11151SM |
| Type | Power Distribution Units |
| Rack Size | 0U |
| Output Connector(s) | C13, C15, C19, and C21 in one outlet |
| Shipping weight | 9.98 kg |
| Package size | 1727 × 216 × 114 mm |
Questions about this item
What rack depth and mounting orientation does the 0U vertical PDU require?
The 0U vertical PDU fits standard server racks and mounts vertically in 0U space; its 2.2 in (5.6 cm) width leaves maximum room for equipment.
How is the NEMA L6-30P input cord connected, and what step is often missed?
Plug the 9.84 ft NEMA L6-30P cord into a 208 V 30 A branch circuit; the step often missed is securing the cord with the supplied strain-relief bracket so the plug cannot pull loose.
When should the NMC3 network management card be replaced, and how?
Replace the NMC3 only if it fails; it supports live swap so you can remove and insert a new card without powering down the PDU or connected equipment.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



