We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC APDU10452MO NetShelter PDU 3-Phase 17.3kW 208V 60A 42 Outlets 21x C13/C15 21x C13/C15/C19/C21 5.91ft Cord

SKU CH-FM0X-STFE8 MPN APDU10452MO

Distributes 17.3 kW across 42 combination IEC 60320 outlets with per-outlet metering in a 0U vertical form factor

  • TypePDUs & Line Conditioners
  • Rack Size0U
  • Metered outlet and PDU-level power monitoring with overload alerts
  • 42 outlets in a 2.2 inch wide 0U vertical form factor
  • 21 C13/C15 plus 21 combo C13/C15/C19/C21 outlets for flexible device connections
  • Alternating phase design simplifies cord routing and promotes load balancing
  • Rated for 60 °C (140 °F) operation at full 17.3 kW load

Three-Phase 17.3 kW PDU for High-Density Racks

This metered outlet PDU delivers three-phase power at 208 V and 60 A to server and networking cabinets. It provides 42 outlets in a 2.2 inch wide 0U vertical form factor. Outlet and PDU level metering gives visibility into power use and warns of potential overload. The unit suits environments that need dense, monitored power distribution.

60 °C Operating Rating with Alternating Phase Layout

The PDU is rated to run at full load up to 60 °C (140 °F), supporting high-density deployments without derating. An alternating phase design organises the three phases into small outlet groups from top to bottom. This arrangement improves cord routing and encourages balanced loading across phases. Color coded outlets and breaker labels simplify identification during installation and maintenance.

Cascaded Power Sharing and Live Swap NMC

Two Ethernet ports allow PDUs to cascade so a Network Management Card stays online if AC power is lost on one unit. Network communication, sensor operation and alarm traps continue without interruption. The NMC can be replaced without powering down the PDU or connected equipment, reducing downtime during a card failure. TAA compliance meets government procurement requirements.

Highlights

  • Metered outlet and PDU-level power monitoring with overload alerts
  • 42 outlets in a 2.2 inch wide 0U vertical form factor
  • 21 C13/C15 plus 21 combo C13/C15/C19/C21 outlets for flexible device connections
  • Alternating phase design simplifies cord routing and promotes load balancing
  • Rated for 60 °C (140 °F) operation at full 17.3 kW load

Specifications

BrandAPC
SeriesNetShelter Rack
ModelAPDU10452MO
Part NumberAPDU10452MO
TypePDUs & Line Conditioners
Rack Size0U
Shipping weight14.06 kg
Package size1981 × 254 × 254 mm

Questions about this item

How do I mount the 0U PDU vertically in a rack and avoid the common mistake of misaligning the alternating-phase outlet groups?

Use the color-coded and phase-labeled outlets that alternate from top to bottom; the 2.2-inch wide form factor fits standard rack channels, and aligning each group to its breaker prevents load imbalance.

Which component will need replacement first under continuous operation at full load?

The Live Swap Network Management Card is designed for replacement without powering down the PDU or connected devices, minimizing downtime during a power event.

At what ambient temperature does the 17.3kW 208V 60A rating reach its limit?

The unit is rated and approved to operate up to 60C (140F) at full load, so sustained use beyond that temperature is the first limiting factor.