We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC APDU10452ME Metered PDU 3Phase 17.3kW 208V 60A 42 Outlet

SKU CH-2NSZ-PBB42 MPN APDU10452ME

A metered 3-phase PDU delivers 17.3 kW at 208 V through 42 combination outlets in a 2.2 inch 0U form factor

  • TypeMetered
  • Metered monitoring enables real-time power visibility and overload alerts
  • 42 combination outlets support C13, C15, C19 and C21 plugs in one unit
  • 3-phase 208 V 60 A input delivers 17.3 kW capacity for high-density racks
  • 0U vertical design fits 2.2 inch width to maximise rack space
  • 8 m cable with IEC 60309 60 A 3P+PE plug ensures secure three-phase connection

Rack PDU with 42 combination outlets

This APC NetShelter Metered PDU distributes three-phase 208 V power to IT equipment in server and networking racks. It delivers 17.3 kW through a 60 A IEC 60309 3P+PE input connection. Forty-two 4-in-1 combination outlets accept C13, C15, C19 or C21 plugs for flexible device deployment. The unit mounts in zero rack units with a 2.2 inch wide form factor and includes a 1.8 m input cable.

Upgrade from unmetered or single-phase strips

Replaces basic power strips that lack per-outlet or aggregate metering, removing blind spots when capacity planning. The jump is worth it when you need real-time visibility of 208 V three-phase loads up to 60 A and remote outlet switching to reboot hung gear without a site visit. Colour-coded outlets grouped by breaker and phase simplify moves, adds and changes compared with unlabelled alternatives.

Fits zero-U vertical space in standard racks

The 2.2 inch width leaves maximum room for cable routing alongside patch panels and switches. Alternating-phase outlet groups reduce cord clutter and promote balanced loading across all three phases. Dual Ethernet ports enable cascaded Power Sharing so the Network Management Card stays online during an AC loss on one unit. The Live Swap NMC can be replaced without powering down connected equipment, preserving uptime during maintenance.

Highlights

  • Metered monitoring enables real-time power visibility and overload alerts
  • 42 combination outlets support C13, C15, C19 and C21 plugs in one unit
  • 3-phase 208 V 60 A input delivers 17.3 kW capacity for high-density racks
  • 0U vertical design fits 2.2 inch width to maximise rack space
  • 8 m cable with IEC 60309 60 A 3P+PE plug ensures secure three-phase connection

Specifications

TypeMetered
Shipping weight13.15 kg
Package size2083 × 254 × 152 mm

Questions about this item

What rack width does the 2.2" form factor fit?

The 2.2 inch wide chassis mounts in standard 19 inch racks as a zero U vertical unit.

Which input plug must the facility provide for the IEC 60309 60 A 3P+PE connection?

A matching IEC 60309 60 amp three phase plus protective earth receptacle is required.

How often should the 42 combination outlets be inspected for retention and discoloration?

Inspect all C13, C15, C19 and C21 sockets annually or after any overload event.