APC
APC APDU10450SW Switched PDU 3PH 43.5kW 400V 63A 42 Outlets IEC309
Switched three-phase PDU with 42 combination outlets for C13, C15, C19 and C21 plugs, remote outlet control, power metering and alternating phase layout in a 2.2 inch form factor
- Typebuffer_35355
- Switched outlets enable remote power cycling
- 5 kW three-phase capacity at 400 V
- 42 combination outlets support C13, C15, C19 and C21 plugs
- Alternating phase layout improves cord management and load balancing
- Cascaded PDUs share network management during AC power loss
Switched 3PH PDU for high-density racks
The APC APDU10450SW is a switched power distribution unit built for three-phase 400 V or 415 V supplies. It delivers up to 43.5 kW at 63 A or 34.6 kW at 60 A through 42 combination outlets that accept C13, C15, C19 or C21 plugs. Remote on/off control per outlet lets administrators reboot individual devices without visiting the rack.
Sustained three-phase load handling
The unit alternates phases in small outlet groups from top to bottom, promoting balanced loading across all three phases during continuous operation. Colour-coded and phase-labelled outlets simplify cable tracing when tracing circuits under full load. Cascaded PDUs share power through dual Ethernet ports so the Network Management Card stays online even if one PDU loses AC input, preserving monitoring and alarm traps without interruption.
Dense 2.2-inch form factor with IEC 309 input
A 2.2-inch wide chassis fits 42 outlets in minimal rack space while the IEC 309 connector matches industrial three-phase feeds. The live-swap Network Management Card can be replaced without powering down the PDU or connected equipment, avoiding downtime during maintenance. Buyers needing fewer outlets or single-phase input should consider alternative models.
Highlights
- Switched outlets enable remote power cycling
- 5 kW three-phase capacity at 400 V
- 42 combination outlets support C13, C15, C19 and C21 plugs
- Alternating phase layout improves cord management and load balancing
- Cascaded PDUs share network management during AC power loss
Specifications
| Type | buffer_35355 |
|---|---|
| Shipping weight | 12.84 kg |
| Package size | 1826 × 75 × 56 mm |
Questions about this item
How much heat does the APDU10450SW generate when running at its 43.5 kW rating all day?
The unit distributes up to 43.5 kW at 400 V three-phase; heat output scales with the actual load drawn by connected equipment rather than the PDU's maximum rating.
Which plugs must my servers already have to use the 42 combination outlets on this PDU?
Each outlet accepts C13, C15, C19 or C21 plugs, so existing equipment with any of those IEC connectors will fit without adapters.
Can the APDU10450SW share network management with an older PDU that has dual Ethernet ports?
Yes, two Ethernet ports allow cascading so a single Network Management Card stays online even if one PDU loses AC power.