We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC APDU10151SW NetShelter Switched PDU 5.0kW 208V 30A L6-30P 40 Outlets

SKU CH-TY0E-3KK7R MPN APDU10151SW

A switched rack PDU delivering 5.0 kW at 208 V with 40 combination outlets and remote on/off control

  • TypeSwitched, Metered
  • Rack Size0U
  • StyleRackmount
  • CertificationsRoHS
  • ROHSYes
  • Input Voltage230V
  • Remotely control each outlet with switched functionality
  • Monitor power usage at outlet and PDU level for overload alerts
  • Fit 40 combination outlets in a 0U vertical form factor
  • Connect via NEMA L6-30P input rated for 30 A at 208 V
  • Mount in standard racks using 58.66-inch height and 2.20-inch width

Switched rack PDU with 40 outlets

The APC NetShelter APDU10151SW is a switched and metered power distribution unit built for server and networking racks. It delivers 5.0 kW at 230 V with a 30 A NEMA L6-30P input plug. Forty combination outlets accept C13, C15, C19 or C21 cords, giving administrators flexible density for mixed equipment. Remote switching lets operators cycle power on individual outlets without visiting the rack.

Zero-U vertical mounting frees horizontal rack space

The 0U form factor mounts in the rear channel of a standard rack, leaving all horizontal U-space for servers and switches. A single L6-30P feed powers the entire strip, reducing the number of upstream circuits required. Each outlet can be switched on or off over the network, so stalled devices can be rebooted remotely. Metering at both the PDU and outlet level provides visibility into actual draw per device.

Metering and switching operate continuously under

Outlet-level current monitoring runs in real time, so administrators see sustained draw rather than only peak spikes. The switched relays are rated for the full 30 A input, allowing any outlet to be cycled while the strip remains fully loaded. RoHS-compliant construction meets environmental requirements for data-centre deployments. The unit is not suited for installations that need a lower input voltage or a different plug type.

Highlights

  • Remotely control each outlet with switched functionality
  • Monitor power usage at outlet and PDU level for overload alerts
  • Fit 40 combination outlets in a 0U vertical form factor
  • Connect via NEMA L6-30P input rated for 30 A at 208 V
  • Mount in standard racks using 58.66-inch height and 2.20-inch width

Specifications

BrandAPC
SeriesNetShelter
ModelAPDU10151SW
Part NumberAPDU10151SW
TypeSwitched, Metered
Rack Size0U
StyleRackmount
CertificationsRoHS
ROHSYes
Input Voltage230V
Maximum Input Current30A
DimensionsHeight: 58.66" (1490 mm)
Width: 2.20" (56 mm)
Depth: 2.95" (75 mm)
Weight7.70 kg
Shipping weight4.54 kg
Package size1778 × 254 × 127 mm

Questions about this item

At what load does the 30 A input breaker become the first limit during sustained use?

The unit is rated for a maximum input current of 30 A; continuous loads should stay below that threshold to avoid tripping the breaker.

How much heat does the PDU add to the rack when it runs at full 5.0 kW load all day?

The PDU itself draws minimal power for metering and switching; virtually all 5.0 kW passes through to connected equipment, so rack heat rise matches the IT load.

Which inlet plug must the facility provide for the NEMA L6-30P on this unit?

The PDU requires a matching NEMA L6-30R receptacle wired for 208 V single-phase service.