APC AP8931 Switched PDU 100-120V 15A 8x 5-15R 0U
Switched PDU distributes 100-120V power to eight NEMA 5-15R outlets with remote on/off control and current metering in a 0U vertical form factor
- TypeSwitched
- CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1,
- ROHSYes
- Input Voltage100V, 120V
- Input Frequency50/60 Hz
- Maximum Input Current15A
- Remote reboot of individual outlets via switched control
- Vertical 0U mounting saves rack space for equipment
- Eight NEMA 5-15R outlets distribute 100-120V power
- Real-time current metering prevents circuit overloads
- Certified to UL 60950-1, cUL, FCC and PSE standards
Switched PDU 1.44 kVA 0U
The APC AP8931 is a switched rack power distribution unit that delivers 100 to 120 volt output through eight NEMA 5-15R receptacles. It mounts vertically in a 0U form factor and includes a ten-foot input cord with a NEMA 5-15P plug. Remote outlet switching and real-time current metering allow administrators to reboot attached gear and monitor load levels from a web, SNMP or Telnet interface.
Suited for 120 V racks needing outlet control
This unit fits server rooms and network closets that run on 100 to 120 volt, 15 amp single-phase power and require individual outlet on/off control, power sequencing or user-defined overload alarms. It is not for installations that need more than eight outlets, input voltages above 120 volts, or current capacity beyond the 12 amp derated limit. The operating range of minus five to forty-five degrees Celsius also rules out extreme-temperature sites.
15 A NEMA 5-15P input decides compatibility
The PDU draws a maximum of fifteen amps through a standard NEMA 5-15P plug, so the upstream circuit and receptacle must match that rating. If the available feed is twenty amps, uses a different connector, or operates at two hundred volts or higher, this model cannot be used.
Highlights
- Remote reboot of individual outlets via switched control
- Vertical 0U mounting saves rack space for equipment
- Eight NEMA 5-15R outlets distribute 100-120V power
- Real-time current metering prevents circuit overloads
- Certified to UL 60950-1, cUL, FCC and PSE standards
Specifications
| Brand | APC |
|---|---|
| Model | AP8931 |
| Type | Switched |
| Certifications | cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed |
| ROHS | Yes |
| Input Voltage | 100V, 120V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 15A |
| Regulatory Derated Input Current | 12A |
| Input Connector(s) | NEMA 5-15P |
| Cord Length | 10 ft |
| Output Voltage | 100V, 120V |
| Output Connector(s) | 8 x NEMA 5-15R |
| Operating Environment | -5 - 45 ºC |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 °C |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | APC Switched Rack PDU - 8 x NEMA 5-15R - 1.44 kVA - 0URack-mountable, Vertical |
| Dimensions | 38.90" x 2.18" x 1.82" (H x W x D) |
| Weight | 9.15 lbs. |
| Shipping weight | 5.44 kg |
| Package size | 1131 × 160 × 108 mm |
Questions about this item
What type of wall outlet is required for the NEMA 5-15P input plug?
A standard 100-120V NEMA 5-15R wall receptacle on a 15A circuit is required to connect the 10 ft input cord.
Can the 15A PDU share a circuit with older 5-15R devices without exceeding the 12A derated limit?
Yes, as long as the combined continuous draw of the PDU and other devices stays at or below 12A to meet the regulatory derated input current.
How do I confirm the unit is monitoring current after network setup?
Log into the Web, SNMP, or Telnet interface and verify real-time current readings appear for each of the eight 5-15R outlets.