We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP8870 Metered PDU 120/208V 30A 16x5-20R 12xC13/C19 0U

SKU CH-7NAG-4VD3M MPN AP8870

Metered PDU delivers 5.76 kVA across 30 outlets with real-time monitoring and IEC locking receptacles

  • TypeSee Details
  • Input Voltage120 V AC 230 V AC
  • Output Voltage120 V AC
  • FeaturesPower Rating:5.76 kVA Form Factor:Horizontal Rackmount Tooll
  • Weight14.04 lb
  • Active metering enables energy optimisation and circuit protection
  • User-defined alarm thresholds give real-time local and remote overload alerts
  • Sixteen 5-20R, twelve C13 and two C19 outlets support dense rack deployments
  • 0U vertical toolless mounting saves rack space
  • 8 ft input cord with NEMA L14-30P plug delivers 5.0 kW at 120/208 V

Metered 30 A rack PDU

The APC AP8870 is a metered power distribution unit built for 120/208 V three-phase circuits rated at 30 A. It delivers 5.76 kVA through a vertical 0U form factor that mounts without tools in standard racks. Data-centre operators and IT managers use it to monitor real-time load on each branch circuit.

Sixteen 5-20R and twelve C13 plus two C19 outlets

The outlet mix supports both North-American locking plugs and IEC 320 equipment without adapters. Locking IEC receptacles prevent accidental disconnects under vibration. A 9.8 ft input cord with NEMA L14-30P plug reaches floor-mounted panels, while the built-in temperature/humidity sensor port adds environmental visibility.

Verify 120/208 V 30 A service

Confirm the facility provides a 120/208 V single-phase 30 A feed with a matching NEMA L14-30R receptacle. Ensure the rack has vertical 0U mounting space and that the 14.04 lb unit does not exceed the rack's load rating. Check that connected devices accept 120 V output and IEC 320 C13 or C19 inlets.

Highlights

  • Active metering enables energy optimisation and circuit protection
  • User-defined alarm thresholds give real-time local and remote overload alerts
  • Sixteen 5-20R, twelve C13 and two C19 outlets support dense rack deployments
  • 0U vertical toolless mounting saves rack space
  • 8 ft input cord with NEMA L14-30P plug delivers 5.0 kW at 120/208 V

Specifications

BrandAPC
ModelAP8870
TypeSee Details
Input Voltage120 V AC
230 V AC
Output Voltage120 V AC
FeaturesPower Rating:5.76 kVA
Form Factor:Horizontal Rackmount
Toolless-mount
Vertical Rackmount
Product Type:PDU
Color:Black
Power Rating:5.76 kVA
Form Factor:Horizontal Rackmount
Toolless-mount
Vertical Rackmount
Input Receptacles:NEMA L14-30P
Product Name:Metered Rack PDU
Output Receptacles:12 x IEC 60320 C13
16 x NEMA 5-20R
2 x IEC 60320 C19
Package Contents:
Metered Rack PDU
Installation Guide
Rack Mounting Brackets
Safety Guide
Serial Configuration Cable
Weight14.04 lb
Shipping weight6.44 kg
Package size1991 × 157 × 109 mm

Questions about this item

Will the IEC C13 and C19 outlets need periodic retightening to maintain a secure connection?

The IEC 320 C13 and C19 receptacles are locking type, designed to resist vibration and prevent accidental disconnection without routine retightening.

At what load does the ultra low profile circuit breaker trip on the 30 A input?

The branch circuit breaker protects the 30 A NEMA L14-30P input and will trip if total draw exceeds 30 A, limiting sustained use to 5.0 kW.

How much heat does the unit add to the rack when running at full 5.76 kVA metered load?

The PDU itself consumes minimal power for metering and network functions; nearly all 5.76 kVA passes through to connected equipment, so rack heat rise matches the IT load.