Anvil 0500173109 Adjustable Clevis Hanger Trap
Adjustable clevis hanger suspends 4-inch stationary pipe lines with a 1,430 lb maximum load
- TypeDrain Components
- Adjustable design fits 4 in pipe lines
- Carbon steel construction supports 1430 lb loads
- Meets A-A-1192A and ANSI/MSS SP-69 standards
- UL and FM approved for code compliance
- Plain steel finish resists corrosion in installations
Adjustable Clevis Hanger for 4-Inch Pipe
The Anvil 0500173109 is a carbon steel clevis hanger designed to suspend stationary pipe lines. It fits a 4-inch pipe size and accepts a 5/8-inch rod. The hanger provides a maximum load capacity of 1430 pounds and measures 7 13/16 inches in length. It is UL, ULC listed and FM approved for code-compliant installations.
Replaces Fixed or Undersized Hangers
This adjustable hanger replaces fixed-position supports when vertical alignment must be set on site. It upgrades from lighter-duty hardware when the system demands a 1430-pound working load. The jump is worth it for installers who need on-the-job height adjustment without cutting or welding new brackets.
Limits of Plain Steel and Listed Standards
The plain steel construction offers no inherent corrosion protection, so it is not suited for outdoor or chemically aggressive environments without additional coating. The hanger meets A-A-1192A Type 1, WW-H-171-E Type 1, ANSI/MSS SP-69 and MSS SP-58 Type 1. It does not satisfy requirements for stainless steel or insulated pipe support specifications.
Highlights
- Adjustable design fits 4 in pipe lines
- Carbon steel construction supports 1430 lb loads
- Meets A-A-1192A and ANSI/MSS SP-69 standards
- UL and FM approved for code compliance
- Plain steel finish resists corrosion in installations
Specifications
| Type | Drain Components |
|---|---|
| Brand | Anvil |
| Model | 0500173109 |
Questions about this item
What rod diameter does the 4-inch pipe size clevis hanger accept?
The adjustable clevis hanger is designed for a 5/8-inch rod size to suspend stationary pipe lines.
Which listed standards confirm the hanger meets Type 1 requirements for installation?
It complies with A-A-1192A Type 1, WW-H-171-E Type 1, ANSI/MSS SP-69, and MSS SP-58 Type 1 for proper mounting.
How often should the plain steel finish be inspected for corrosion in a typical plumbing system?
Inspect the carbon steel hanger annually; replace it if rust reduces the 1430-pound maximum load capacity.