Black forged steel merchant coupling rated Class 300 for Schedule 80 pipe, with 1,500 psi maximum operating pressure at 150 degrees F
- TypeDrain Components
- MaterialHAWA
- Class 300 forged steel handles 500 psi at 150 °F
- Taper-tapped NPT threads ensure leak-resistant joints
- Schedule 80 pipe compatibility suits high-pressure systems
- Black finish protects forged steel from corrosion
- 1 1/2 in female NPT fits standard drain assemblies
Taper Tapped Merchant Coupling
This forged steel coupling connects two 1 1/2 inch female NPT threads in Schedule 80 piping systems. It is built to Class 300 pressure ratings for industrial and commercial plumbing installations. The black finish identifies the carbon steel construction used in high-pressure service.
Fit for high-pressure steam or water lines
Suitable for installers joining Schedule 80 pipe where a 500 psi rating at 150 degrees F is required. Not intended for low-pressure residential drainage or systems using thinner wall schedules. Buyers needing welded or flanged connections should look at alternative fitting types.
Class 300 pressure rating
The coupling withstands 500 psi at 150 degrees F, which determines whether it meets the design pressure of the piping system. Verify the operating temperature and pressure against this limit before specifying the part.
Highlights
- Class 300 forged steel handles 500 psi at 150 °F
- Taper-tapped NPT threads ensure leak-resistant joints
- Schedule 80 pipe compatibility suits high-pressure systems
- Black finish protects forged steel from corrosion
- 1 1/2 in female NPT fits standard drain assemblies
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Anvil |
| Model | 0320201072 |
Questions about this item
Will the forged steel coupling need periodic replacement due to corrosion or wear?
The coupling is made from forged steel rated for Schedule 80 pipe and Class 300 service, so under normal conditions it does not require scheduled replacement.
What pressure limit will be reached first during continuous high-pressure operation?
The maximum operating pressure is 500 psi at 150 degrees F, which is the primary limit under sustained use.
Does the coupling generate heat or noise when installed in a system running all day?
As a static forged steel fitting with no moving parts, it produces no noise and negligible heat during continuous operation.