Amprobe
Amprobe SM-CAL1 Sound Level Calibrator 1000 Hz 114 dB
Calibrates sound-level meters at 1000 Hz and 114 dB with ±0.5 dB accuracy
- TypeDigital Multimeters
- Calibrates meters at a precise 1000 Hz reference tone
- Delivers 114 dB output for accurate SPL verification
- Frequency accuracy within ±4 % ensures reliable readings
- Output level held to ±0.5 dB for consistent calibration
- Operates from 32 °F to 104 °F with included 9 V battery
Sound Level Calibrator for SM-10 and SM-20A
The Amprobe SM-CAL1 is a dedicated sound level calibrator designed to verify the accuracy of compatible meters. It serves technicians and engineers who require reliable reference output for SM-10 and SM-20A models during field or bench checks.
114 dB output at 1000 Hz with stated tolerances
The calibrator produces a sound pressure level of 114 dB at a frequency of 1000 Hz. Output sound accuracy is within +/- 0.5 dB while frequency accuracy is held to +/-4 percent. Distortion is limited to +/- 0.5 dB across the operating range of 32 to 104 degrees F.
Includes 1/2 in adapter and 9V alkaline battery
A 1/2 in adapter is supplied to fit the microphone capsules of the listed meters. One 9V alkaline battery is included so the unit is ready for immediate use without additional purchases.
Highlights
- Calibrates meters at a precise 1000 Hz reference tone
- Delivers 114 dB output for accurate SPL verification
- Frequency accuracy within ±4 % ensures reliable readings
- Output level held to ±0.5 dB for consistent calibration
- Operates from 32 °F to 104 °F with included 9 V battery
Specifications
| Brand | AMPROBE |
|---|---|
| Type | Digital Multimeters |
Questions about this item
How do I fit the 1/2 in adapter onto the calibrator for my SM-10 or SM-20A meter?
Push the supplied 1/2 in adapter firmly over the calibrator's output nozzle until it seats fully; the meter's microphone capsule then slides into the adapter for a tight acoustic seal.
What battery will I need to replace and how often?
A standard 9 V alkaline cell powers the unit; replace it when the output level drifts or the calibrator fails to start, typically after many hours of intermittent use.
At what temperature does the calibrator stop meeting its +/-0.5 dB accuracy spec?
The rated accuracy holds between 32 °F and 104 °F; outside that range the 114 dB output at 1000 Hz can deviate by more than the stated tolerance.