3M
3M 8428-12 Cold Shrink Tube 1.94 in 12 in
EPDM rubber cold-shrink tube covers 500-800 MCM wire, shrinking from 1.94 in to .95 in over a 12 in length
- Color MappingBlack
- TypeCable Management & Conduit
- Cold shrink design installs without heat tools
- EPDM rubber withstands -40 °F to 194 °F
- UV-resistant black jacket suits outdoor exposure
- Fits 500 MCM to 800 MCM conductors
- 12 in length covers extended splice areas
Cold Shrink Tube for Large Cable Splices
The 3M 8428-12 is a medium-wall cold shrink insulator designed for wire sizes from 500 MCM to 800 MCM. It installs without heat tools, making it practical for field repairs or permanent splices on large conductors. The tube is supplied as individual pieces ready for immediate use.
EPDM Rubber Withstands Wide Temperature Range
The EPDM rubber material operates from -40 degrees to 194 degrees F and provides UV light resistance for outdoor exposure. It carries a dielectric strength of 1,000 V and is not flame retardant. No adhesive lining is present, so the seal relies on the shrink force alone.
Slides Over 1.94 in Diameter Before Shrinking
The tube arrives with a 1.94 in inside diameter and shrinks to 0.95 in after the core is removed. Its 12 in length covers standard splice areas on the rated wire range. Builders must verify the final diameter fits their specific cable insulation before installation.
Highlights
- Cold shrink design installs without heat tools
- EPDM rubber withstands -40 °F to 194 °F
- UV-resistant black jacket suits outdoor exposure
- Fits 500 MCM to 800 MCM conductors
- 12 in length covers extended splice areas
Specifications
| Brand | 3M |
|---|---|
| Color Mapping | Black |
| Type | Cable Management & Conduit |
Questions about this item
How do you install the 3M 8428-12 cold shrink tube and what step is often missed?
Slide the pre-expanded tube over the cable joint, then unwind the removable core to let the EPDM rubber shrink onto 500–800 MCM wire; the step often missed is confirming the core is fully removed so the tube seats at 0.95 in I.D.
What maintenance or replacement will the 8428-12 tube need later?
The medium-wall EPDM rubber is UV-light-resistant and rated from -40 to 194 °F, so no scheduled maintenance is required; replace only if physical damage or dielectric breakdown above 1,000 V occurs.
What limit appears first on the 3M 8428-12 during sustained use?
The maximum temperature rating of 194 °F is the first limit reached under continuous load; exceeding it can degrade the rubber’s dielectric strength of 1,000 V.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Unique-Bargains 2-Position Speaker Terminal Block 2 Pcs
- HI - Wire & Cable C…



