We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Westward

Westward 19T234 Receptacle Tester GFCI 110 to 125V AC

SKU CH-2WWB-V8EAF

Checks receptacle wiring and GFCI function on 110 to 125V AC circuits with light indicators

  • TypeAssortments & Kits
  • Tests GFCI protection on 110-125V AC circuits
  • Identifies faulty wiring with clear light alerts
  • Checks receptacle wiring on standard 5-15P outlets
  • Operates at 50-60 Hz frequency for mains compatibility
  • Draws 6-9 mA load current during testing

Receptacle Tester for 110-125V AC Circuits

This receptacle tester checks standard North American outlets for correct wiring and GFCI function. It plugs directly into a NEMA 5-15P socket and uses indicator lights to show wiring faults or confirm proper installation. The tool is designed for electricians and maintenance staff verifying 110 to 125V AC circuits.

Limited to 50-60 Hz Mains Frequency

The tester operates only on 50 to 60 Hz AC supplies within the stated voltage range. It carries no CAT safety rating and has no display screen, so it cannot measure voltage levels, impedance or current beyond its basic go/no-go indication. It is unsuitable for industrial high-energy panels or DC systems.

Handles Basic Wiring and GFCI Verification

The unit draws 6 to 9 mA load current to trip a GFCI device and confirm protection is active. It identifies common faults such as open ground, reversed polarity and hot-neutral swap. It does not measure loop impedance, prospective fault current or phase rotation, so advanced diagnostics require separate instruments.

Highlights

  • Tests GFCI protection on 110-125V AC circuits
  • Identifies faulty wiring with clear light alerts
  • Checks receptacle wiring on standard 5-15P outlets
  • Operates at 50-60 Hz frequency for mains compatibility
  • Draws 6-9 mA load current during testing

Specifications

BrandWESTWARD
TypeAssortments & Kits

Questions about this item

Does the Westward 19T234 come in any other voltage ranges or plug types?

The Westward 19T234 is offered only for 110 to 125V AC at 50 to 60 Hz with a NEMA 5-15P plug.

What does the 6 to 9 mA load current do when I press the GFCI test button?

It simulates a ground fault of 6 to 9 mA, causing a working GFCI device to trip and cut power to the outlet.

How does the NEMA 5-15P interface limit what I can test?

The NEMA 5-15P plug fits standard 15 A, 125 V receptacles, so it tests only those outlet types.