Viega
Viega 90400 press-fit cap 1 in stainless steel 316 200 psi 250 °F
Stainless-steel 316 press-fit cap seals 1 in potable-water lines at 200 psi and 250 °F
- Press-fit design speeds installation without threading tools
- 316 stainless steel resists corrosion in potable water systems
- EPDM O-ring seals up to 200 psi and 250 °F
- Certified to NSF/ANSI 372 for lead-free compliance
- Meets ASTM A312, A403 and ASME B31 piping codes
Press-fit cap for 1 in stainless steel systems
The Viega 90400 cap terminates a 1 in press-fit line in potable-water installations. Its 316 stainless body and EPDM O-ring suit residential and light-commercial plumbing where corrosion resistance and clean-water compliance are required. The fitting meets ASTM A312, ASTM A403, NSF/ANSI 372 and multiple ASME/TSSA B31 codes. Installers needing a permanent, leak-free end point on 1 in tubing will find it a direct fit.
Rated for 200 psi and 250 °F in normal service
The cap withstands 200 psi maximum operating pressure and 250 Degrees F maximum operating temperature without degrading the EPDM seal. Stainless 316 construction resists scaling and chemical attack, so thermal cycling in hot-water loops does not accelerate fatigue. No moving parts means zero vibration noise and no pressure-drop penalty across the fitting. The press joint remains tight through daily pressure swings.
2 7/16 in overall length with no centre stop
The compact 2 7/16 in body leaves maximum clearance in tight joist bays or service walls. Absence of a centre stop lets the press tool seat fully, giving a consistent crimp profile every time. Stainless 316 threads and sealing surfaces resist galling during installation and later disassembly if the line is reconfigured. Standard press jaws for 1 in fittings engage the cap without adapters.
Highlights
- Press-fit design speeds installation without threading tools
- 316 stainless steel resists corrosion in potable water systems
- EPDM O-ring seals up to 200 psi and 250 °F
- Certified to NSF/ANSI 372 for lead-free compliance
- Meets ASTM A312, A403 and ASME B31 piping codes
Specifications
| Brand | VIEGA |
|---|
Questions about this item
How do I press the 90400 cap onto 1 in stainless pipe without missing the center stop?
Use a Viega-approved press tool with the correct 1 in jaw set, apply even force until the tool completes its cycle, and verify the press indicator ring is fully engaged; the cap has no separate center stop to align.
When should the EPDM O-ring on this 316 stainless press-fit cap be inspected or replaced?
Inspect the EPDM O-ring during any system pressure test or after exposure near the 250 °F temperature limit; replace it if you see cracking, hardening, or permanent compression set.
At what pressure will the 90400 cap reach its rated limit during sustained hot-water service?
The cap is rated for a maximum operating pressure of 200 psi at temperatures up to 250 °F; sustained operation at that pressure and temperature combination is the design limit.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor Made 12" x 18" Jolly Roger Novelty Flag 1818 marine electronic
- Accessories