VEVOR
VEVOR 0.75HP 1725RPM AC 115V/230V 56 Frame 5/8" Keyed Shaft CW/CCW
Dual-voltage 0.75 HP motor runs at 1725 RPM on 115 V or 230 V with reversible CW/CCW rotation and a 5/8" keyed shaft
- TypeOther Appliances
- Width11.02
- 75 HP motor delivers strong torque for pumps and farm equipment
- Dual-voltage 115 V / 230 V design fits standard or high-voltage circuits
- Reversible CW/CCW rotation simplifies wiring for any mounting orientation
- 56-frame steel housing with overload protection extends service life
- 5/8 in keyed shaft with 0.188 in keyway matches common couplings
0.75 HP dual-voltage motor for farm and workshop use
This single-phase motor delivers 0.75 HP at 1725 RPM from a 56 frame with a 5/8" keyed shaft. It runs on either 115 V or 230 V AC at 60 Hz and draws 12.0 A on the lower voltage or 6.0 A on the higher voltage. The reversible CW/CCW rotation suits water pumps, agricultural machinery and general equipment replacements.
CSA-tested steel shell
The rolled steel enclosure meets CSA standards and includes a built-in overload protector that can be reset by hand. A 1.15 service factor provides margin for intermittent loading. The package weighs 27.1 lbs and measures 12.4 x 9.1 x 8.3 in for bench handling.
User manual only — no wiring hardware
The box contains a single user manual with installation guidance. Buyers must source their own power cord, starter components, pulleys, couplings and mounting bolts. Builders who need a complete plug-and-play kit or a different shaft diameter will need additional parts.
Highlights
- 75 HP motor delivers strong torque for pumps and farm equipment
- Dual-voltage 115 V / 230 V design fits standard or high-voltage circuits
- Reversible CW/CCW rotation simplifies wiring for any mounting orientation
- 56-frame steel housing with overload protection extends service life
- 5/8 in keyed shaft with 0.188 in keyway matches common couplings
Specifications
| Type | Other Appliances |
|---|---|
| Width | 11.02 |
Questions about this item
How do I wire the motor for 115 V or 230 V and which step is often missed?
Connect the dual-voltage leads to match your supply — 115 V or 230 V — and set the rotation to CW or CCW as needed; the step often missed is moving the internal jumper links to the correct voltage taps before applying power.
What maintenance does the overload protection and bearings require over time?
The manual-reset overload button should be pressed only after the motor cools; bearings are sealed and need no lubrication, but inspect the 5/8" keyed shaft and 0.188" keyway periodically for wear or fretting.
At what load does the 1.15 service factor limit continuous operation?
The 1.15 service factor allows short-term overloads up to roughly 15 % above the 0.75 HP nameplate rating; sustained operation beyond that will trip the overload protection and shorten winding life.