We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Velvac

Velvac 032135 Drain Pull Valve 1/4" NPT 120 PSI

SKU CH-3JM8-NGDJP

Drains air lines with a 1/4" NPT pull valve rated for 120 PSI and a 3 ft cable

  • Easy tank draining with a simple pull action
  • 1/4" NPT male threads connect directly to standard fittings
  • Rated for 120 PSI maximum operating pressure
  • Three-foot cable allows remote operation from a distance
  • Threaded body style ensures a secure, leak-resistant seal

Air-system drain valve

The Velvac 032135 is a pull-operated drain valve with 1/4 inch NPT male threads on both inlet and outlet. It is designed for technicians and fleet operators who need a simple way to remove moisture and contaminants from compressed-air lines.

120 PSI operating limit

The valve is rated for a maximum operating pressure of 120 psi, suitable for standard shop and mobile air systems. A 3-foot pull cable lets the user actuate the drain from a convenient location without reaching into tight or hot areas.

Threaded inline installation

The threaded body installs directly into existing 1/4 inch NPT ports, so no extra fittings or adapters are required. Its compact pull-cable design frees up space around the tank or filter housing while keeping the drain point accessible.

Highlights

  • Easy tank draining with a simple pull action
  • 1/4" NPT male threads connect directly to standard fittings
  • Rated for 120 PSI maximum operating pressure
  • Three-foot cable allows remote operation from a distance
  • Threaded body style ensures a secure, leak-resistant seal

Specifications

BrandVELVAC

Questions about this item

How do I install the 1/4" NPT male threads without cross-threading?

Start both male threads by hand until they seat fully, then tighten with a wrench on the valve body — not the cable — to avoid stripping the 1/4" NPT connections.

What part of this drain valve will need replacement first?

The 3 ft pull cable and its attachment point wear with repeated cycling; inspect the cable for fraying and the valve seat for leaks during routine air-system maintenance.

At what pressure does the valve reach its rated limit during continuous operation?

The maximum operating pressure is 120 psi; sustained use at or above this pressure can cause the valve seat to leak or the body to deform.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.