Value Brand
Value Brand 5P527 Hex Bushing 2" x 3/4" FNPT x MNPT
A 2-inch to 3/4-inch NPT hex bushing made from Class 150 malleable iron for pipe connections
- Hex bushing connects 2 in and 3/4 in NPT threads
- Malleable iron construction rated for Class 150 service
- Female-to-male NPT configuration simplifies pipe reductions
- 11 1/2 and 14 threads per inch ensure proper engagement
- ZORO SELECT brand supplied as new condition fitting
Value Brand 5P527 Hex Bushing 2" x 3/4
This malleable iron hex bushing reduces a 2 inch female NPT thread to a 3/4 inch male NPT thread. It is rated for Class 150 pressure service. The fitting suits installers who need a durable transition between dissimilar pipe sizes in water, oil or air lines.
Fits 2 inch to 3/4 inch NPT reduction only
The bushing matches systems using 11 1/2 TPI on the large end and 14 TPI on the small end. It will not suit metric threads, BSP fittings or any other pitch. Installers needing a coupling, an elbow or a different size step should select another fitting.
Class 150 malleable iron rating
The Class 150 designation defines the pressure envelope for this fitting at standard temperatures. Systems operating above that rating require a higher-class component. Verify the service pressure before installation to ensure the part meets the application demands.
Highlights
- Hex bushing connects 2 in and 3/4 in NPT threads
- Malleable iron construction rated for Class 150 service
- Female-to-male NPT configuration simplifies pipe reductions
- 11 1/2 and 14 threads per inch ensure proper engagement
- ZORO SELECT brand supplied as new condition fitting
Specifications
| Brand | ZORO SELECT |
|---|
Questions about this item
How do I install this 2 inch by 3/4 inch hex bushing and what step is often missed?
Thread the male NPT end into the female fitting using pipe sealant on the 11 1/2 threads per inch side, then tighten with a wrench on the hex; the step often missed is applying sealant to both the 11 1/2 and 14 thread ends to prevent leaks.
What maintenance or replacement will this malleable iron Class 150 bushing need over time?
Inspect the hex bushing periodically for corrosion or thread damage; replace it if the iron shows cracking or if the NPT threads no longer seal properly after reapplication of thread sealant.
What pressure or temperature limit appears first during sustained use of this Class 150 fitting?
The Class 150 rating defines the maximum working pressure limit; sustained pressure above this rating will cause failure before any temperature limit is reached in typical plumbing service.