Value Brand
Value Brand 24W702 Hydraulic Reservoir 8 gal Steel
An 8-gallon steel hydraulic reservoir with removable cover, breather cap, 1-1/2 in NPT suction port, 3/4 in NPT return and drain ports, Buna-N gasket, black painted finish.
- 8-gallon capacity supports extended hydraulic runs
- 11-gauge steel tank resists pressure and impact
- Vertical mounting orientation fits power-unit installations
- Removable cover and breather cap simplify maintenance
- 1-1/2 in NPT suction and 3/4 in NPT return ports enable direct plumbing
8 gal Steel Hydraulic Reservoir
This 8 gal steel hydraulic reservoir is built for vertical power-unit installations where a compact footprint is required. It suits maintenance teams and OEM integrators who need a ready-to-mount tank with standard NPT ports for suction, return and drain connections.
Thermals Noise and Power Draw
The tank relies on natural convection through its 11 ga steel walls and the included breather cap to dissipate heat during normal operation. No fan or pump is integrated, so the reservoir adds no audible noise or electrical load to the hydraulic system.
Removable Cover and Buna-N Gasket
A removable cover with a Buna-N gasket allows direct access for cleaning, inspection or filter servicing without disconnecting plumbing. The black painted finish and factory-fitted 1-1/2 in suction, 3/4 in return and 3/4 in drain ports reduce assembly time on the shop floor.
Highlights
- 8-gallon capacity supports extended hydraulic runs
- 11-gauge steel tank resists pressure and impact
- Vertical mounting orientation fits power-unit installations
- Removable cover and breather cap simplify maintenance
- 1-1/2 in NPT suction and 3/4 in NPT return ports enable direct plumbing
Specifications
| Brand | Zoro Select |
|---|
Questions about this item
How is the 8 gal steel reservoir mounted and which step is often missed?
Mount the unit vertically on power units using the 14.25 in length and 12 in width footprint; the step often missed is installing the Buna-N gasket under the removable cover before tightening.
What maintenance will the 8 gal hydraulic reservoir need over time?
Periodically remove the breather cap to clean or replace the filter element, drain fluid through the 3/4 in NPT drain plug, and inspect the Buna-N gasket on the removable cover for cracks.
What limit appears first during sustained operation of the 8 gal steel tank?
The 11 ga steel wall and black painted finish dissipate heat only passively, so fluid temperature rise becomes the limiting factor before the 18.125 in height or 8 gal capacity is reached.
Also in this aisle
People compared these