Value Brand
Value Brand 12U634 Analog Panel Mount Thermometer 0-100F
Analog panel-mount thermometer reads 0 to 100 °F with a 60-inch capillary tube and stainless-steel case
- TypeEnvironmental & Mechanical
- Vapor-actuated accuracy within ±1 scale division
- Fahrenheit range from 0 to 100 degrees
- Celsius range from 17 to 37 degrees
- 60 inch capillary tube for remote sensing
- Stainless steel case with polycarbonate lens
Panel Mount Thermometer 0-100F
The Value Brand 12U634 is an analog panel mount thermometer designed for monitoring temperature in industrial or mechanical systems. It uses a vapor actuated sensing method with a copper sensor and bronze braided copper tube. Installers mount the 3 1/2 inch dial directly onto a panel surface with a bottom outlet connection.
Thermals Noise Power
The instrument operates without external power so it produces no electrical noise and draws no current. Its stainless steel case and polycarbonate lens resist ambient heat while the 60 inch capillary tube isolates the dial from the process temperature. Accuracy is rated at plus or minus one scale division across the full range.
Temperature Range 0-100F
The scale covers 0 to 100 degrees Fahrenheit with a Celsius equivalent of 17 to 37 degrees. The copper sensor measures 1.87 inches long by .437 inches in diameter and connects via a 1/2 inch NPT fitting. Buyers who need a wider temperature span or digital readout must choose a different instrument.
Highlights
- Vapor-actuated accuracy within ±1 scale division
- Fahrenheit range from 0 to 100 degrees
- Celsius range from 17 to 37 degrees
- 60 inch capillary tube for remote sensing
- Stainless steel case with polycarbonate lens
Specifications
| Brand | Zoro Select |
|---|---|
| Type | Environmental & Mechanical |
Questions about this item
How do I install the 1/2 in NPT sensor on a panel and what step is often missed?
Thread the copper sensor into a 1/2 in NPT fitting, route the 60 in bronze-braided capillary tube without kinking, then clamp the 3 1/2 in stainless case into the panel cut-out; the step most often missed is leaving enough capillary slack so vibration does not stress the sensor connection.
What maintenance will the vapor-actuated analog panel mount thermometer need over time?
Check the polycarbonate lens for crazing, verify the bronze-braided capillary tube has not work-hardened at bends, and recalibrate against a reference if the pointer drifts beyond one scale division.
At what temperature does the 0-100 °F dial reach its limit during sustained use?
The dial stops indicating at 100 °F; sustained exposure above that point will not show higher readings and can permanently shift the vapor-actuated movement.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Keson MP301 Measuring Wheel Orange Tubular Steel Frame Metal Spoked Wheel 999Ft
Bazarc Auto Lock Inspection Loop Amber/Blue measurement tool
- Amber/Blue



