Value Brand
Value Brand 1" CTS Hub CPVC 90 Degree Elbow SDR-11
A CPVC 90-degree elbow fitting with CTS hub connection for 1-inch pipe, rated to 100 psi and 180°F per ASTM D2846
- 90-degree turn routes CPVC lines efficiently
- SDR-11 wall handles 100 psi at 180°F
- CTS hub fits 1-inch copper-tube-size pipe
- Meets ASTM D2846 standard for hot-water systems
- Light yellow colour identifies CPVC material quickly
Application Scope
This 1 inch CTS hub CPVC elbow forms a 90 degree turn in copper tube size piping systems. It is intended for installers joining Schedule SDR-11 pipe in hot or cold water distribution. The fitting meets ASTM D2846 requirements for CPVC plumbing components.
Thermal and Pressure Limits
Rated for continuous service at 180 degrees F and a maximum working pressure of 100 psi. CPVC material resists scaling and corrosion under these conditions without adding noise or vibration to the line. The light yellow colour identifies the fitting visually during inspection.
Connection and Compliance
The hub ends accept 1 inch CTS pipe for solvent cement assembly, creating a permanent joint that does not require threading tools. California Proposition 65 warnings apply because the product contains chemicals linked to cancer and reproductive harm. The item is not restricted from sale in any listed state.
Highlights
- 90-degree turn routes CPVC lines efficiently
- SDR-11 wall handles 100 psi at 180°F
- CTS hub fits 1-inch copper-tube-size pipe
- Meets ASTM D2846 standard for hot-water systems
- Light yellow colour identifies CPVC material quickly
Specifications
| Brand | ZORO SELECT |
|---|
Questions about this item
How do I solvent-weld the 1" CTS hub on this CPVC elbow and what step causes most leaks?
Clean and dry both hub and pipe, apply CPVC cement evenly, insert fully with a quarter turn, and hold for the recommended set time; skipping the quarter turn or releasing too early leaves a gap that leaks at 100 psi.
Will the SDR-11 CPVC material need replacement due to heat or chemical exposure?
The fitting is rated to 180 °F and meets ASTM D2846 for hot water service; it does not degrade under normal potable-water chemistry, so replacement is only needed if the system exceeds the temperature or pressure limits.
What pressure limit will I hit first if I run this elbow continuously at high flow?
The maximum working pressure is 100 psi; sustained operation above that pressure will stress the SDR-11 wall before any temperature limit is reached.