Tripp Lite
Tripp Lite PDUMV20HVNETLX Switched PDU 3.2-3.8kW 200-240V 24 Outlets
A switched PDU delivering 3.2 to 3.8 kW across 24 locking outlets with remote network control and real-time load monitoring
- Advanced network control with remote outlet switching
- 24 switched outlets (20 C13, 4 C19) with plug-lock inserts
- Real-time load monitoring via digital ammeter per bank
- 2-3.8 kW capacity at 200-240V single-phase power
- Java-free HTML5 LX Platform for secure browser, SNMP, SSH access
Switched PDU for IT Racks
The Tripp Lite PDUMV20HVNETLX is a single-phase switched power distribution unit built for server rooms and industrial racks. It delivers 3.2 to 3.8 kW over 200 to 240 V input. Twenty-four individually switched outlets let administrators cycle power remotely. The vertical 0U form factor fits standard cabinets without consuming rack units.
Network Interface and Protocols
A built-in LX Platform interface provides Java-free HTML5 access through any secure web browser. It speaks HTTP, HTTPS, SNMP v1 through v3, SSH, telnet, FTP, DHCP and NTP over a 10/100 Mbps Ethernet link. Remote users can reboot outlets, set schedules and receive email alerts without proprietary software. The 10-foot cord with NEMA L6-20P plug connects to a compatible UPS or generator source.
Outlet Mix and Load Visibility
Twenty C13 and four C19 outlets accept common server and network gear plugs. Included lock-insert sleeves prevent accidental cable disconnection. A digital ammeter reports each bank’s current draw in real time so operators can keep loads well below the 3.8 kW ceiling. Optional EnviroSense2 modules add temperature and humidity sensing when environmental data is required.
Highlights
- Advanced network control with remote outlet switching
- 24 switched outlets (20 C13, 4 C19) with plug-lock inserts
- Real-time load monitoring via digital ammeter per bank
- 2-3.8 kW capacity at 200-240V single-phase power
- Java-free HTML5 LX Platform for secure browser, SNMP, SSH access
Specifications
No published specifications for this item yet.
Questions about this item
Should I use the 20 C13 outlets or the 4 C19 outlets for my equipment?
The unit provides 20 C13 outlets and 4 C19 outlets; match each outlet to the plug type on your device's power cord.
What does the 3.2-3.8 kW rating mean for my rack deployment?
It indicates the maximum total power the PDU can distribute across all 24 outlets depending on whether the supply is 200 V or 240 V.
What network connection does the LX Platform use and what speed does it support?
The built-in interface connects via 10/100 Mbps Ethernet for remote monitoring and outlet control through a web browser, SNMP or SSH.