Tork
Tork ZSS124 Photocontrol 120-277V 2220W
A compact 120-277 V AC photocontrol rated 2220 W for LED, HID, inductive and fluorescent loads, switching at 1.5 fc on and 2.25 fc off with a -40 °F to 158 °F operating range
- typeIndustrial Electrical Controls & Automation
- Automatic dusk-to-dawn lighting at 1.5 foot-candles on / 2.25 foot-candles off
- Handles up to 2,220 watts across 120-277 V AC circuits
- SPST contact rated 15 A incandescent / 8 A ballast for reliable switching
- Polycarbonate housing withstands -40 °F to 158 °F extremes
- UL listed and ANSI compliant for code-approved installations
Industrial Photocontrol 120–277 V AC
The Tork ZSS124 is a swivel-mount photocontrol rated for 120 to 277 V AC and a maximum load of 2,220 W. It switches lighting circuits on at 1.5 foot-candles and off at 2.25 foot-candles. The unit carries UL listing and ANSI compliance for commercial and industrial installations. Gray polycarbonate housing protects the SPST contact in ambient temperatures from -40 to 158 °F.
Voltage and Load Limits
The device operates across a 120 to 277 V AC supply without separate taps. Resistive loads up to 15 A and ballast loads up to 8 A are supported within the 2,220 W ceiling. Exceeding either current rating risks contact welding or premature failure. No dimming or multi-level control is provided; the relay is strictly on/off.
Swivel Mount and Polycarbonate Housing
A built-in swivel conduit mount lets the sensor head rotate for optimal sky exposure after the conduit is secured. The compact 2 × 2 3/4 × 4 1/4 in polycarbonate body resists UV degradation and impact. SPST wiring uses standard pigtails inside the conduit hub. The fixed 1.5 / 2.25 fc thresholds cannot be adjusted in the field.
Highlights
- Automatic dusk-to-dawn lighting at 1.5 foot-candles on / 2.25 foot-candles off
- Handles up to 2,220 watts across 120-277 V AC circuits
- SPST contact rated 15 A incandescent / 8 A ballast for reliable switching
- Polycarbonate housing withstands -40 °F to 158 °F extremes
- UL listed and ANSI compliant for code-approved installations
Specifications
| Brand | NSI TORK |
|---|---|
| type | Industrial Electrical Controls & Automation |
Questions about this item
What does the 2,220 W rating mean for the lighting load I can connect?
The 2,220 W maximum wattage is the total connected load the photocontrol can switch on a 120 to 277 V AC circuit, covering compact fluorescent, HID, inductive and LED fixtures.
How do the 1.5 and 2.25 foot-candle thresholds work once the unit is installed?
The photocontrol turns the load on when ambient light falls to 1.5 foot-candles and turns it off again when light rises to 2.25 foot-candles, providing a built-in hysteresis band.
What does the SPST contact form and UL listing cap in practice?
The single-pole single-throw contact switches one circuit up to 15 A incandescent or 8 A ballast, and the UL listing confirms it meets the ANSI safety standard for that rating.