We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tempco

Tempco MTA01183 Pipe Clamp Thermocouple J 7/8 to 1 1/2In hvac control

SKU CH-QGCV-XHN6A

Pipe clamp thermocouple Type J fits 7/8 to 1-1/2 inch pipes for HVAC control

  • ColorTransparent
  • Type J thermocouple clamps 7/8 to 1 1/2 in pipe
  • Grounded junction gives fast response in HVAC ducts
  • Probe fits 3/16 in x 24 in openings
  • Standard plug connects to common controllers
  • Operates 32 to 300 °F (0 to 260 °C)

HVAC Pipe Clamp Thermocouple

The Tempco MTA01183 is a Type J pipe clamp thermocouple designed for HVAC control systems. It fits pipe diameters from 7/8 to 1 1/2 inches and provides reliable temperature sensing for heating and cooling equipment.

Grounded Junction With Standard Plug

The grounded junction delivers fast response times by placing the sensing element in direct contact with the probe sheath. A standard plug ensures compatibility with common HVAC controllers and data loggers without requiring special adapters or wiring harnesses.

32 to 300 Degrees F Operating Range

This thermocouple operates from 32 degrees to 300 degrees Fahrenheit, covering typical HVAC supply and return air temperatures. Systems requiring measurement above 300 degrees F or below freezing need a different sensor specification.

Highlights

  • Type J thermocouple clamps 7/8 to 1 1/2 in pipe
  • Grounded junction gives fast response in HVAC ducts
  • Probe fits 3/16 in x 24 in openings
  • Standard plug connects to common controllers
  • Operates 32 to 300 °F (0 to 260 °C)

Specifications

BrandTEMPCO
ColorTransparent

Questions about this item

Will the grounded Type K junction need periodic recalibration after repeated thermal cycles?

The grounded junction is built for continuous duty up to 1260 °C; no scheduled recalibration interval is defined by the manufacturer.

What temperature ceiling stops the probe from reading higher during prolonged exposure?

The upper limit is 1260 °C (2300 °F); sustained operation beyond that point will exceed the sensor's rated range.

How much heat does the 3/16 in sheath add to a duct when the probe runs all day?

The slender sheath contributes negligible thermal mass, so it does not measurably raise duct temperature during continuous use.