Telemecanique Sensors XCKJ10559H7 Heavy Duty Limit Switch Adjustable Rod 1NC/1NO 10A 240V
Heavy-duty limit switch with adjustable 8.35 in rod, 1NC/1NO contacts rated 10 A at 240 V AC/DC, NEMA 1, 2, 4, 12, 13 enclosure
- Heavy-duty switching handles 10 A at 240 V AC and DC
- Adjustable rod actuator extends 8.35 in for flexible positioning
- NEMA 1, 2, 4, 12 and 13 ratings suit indoor and outdoor use
- Compact body 4.01 in high, 1.57 in wide, 2.36 in deep fits tight enclosures
- 1 NC / 1 NO contact form provides both safety and signal circuits
Industrial Limit Switch
The Telemecanique Sensors XCKJ10559H7 is a heavy-duty limit switch designed for industrial automation and safety circuits. It features an adjustable rotary rod actuator mounted on the side of the standard body. The switch provides one normally closed and one normally open contact for versatile control logic.
Electrical Ratings & Environment
The switch carries a 10A rating at 240V for both AC and DC loads, making it suitable for a range of power circuits. Its enclosure meets NEMA 1, 2, 4, 12 and 13 ratings, offering protection against dust, falling dirt and water ingress in indoor and outdoor settings. No boot seal is fitted to the actuator.
Mechanical Build & Mounting
The body measures 4.01 in high, 1.57 in wide and 2.36 in deep, with an 8.35 in adjustable rod length for flexible trip-point positioning. The standard body style allows straightforward mounting on machinery frames or panels. Buyers needing a sealed actuator boot or a different contact configuration should verify compatibility before ordering.
Highlights
- Heavy-duty switching handles 10 A at 240 V AC and DC
- Adjustable rod actuator extends 8.35 in for flexible positioning
- NEMA 1, 2, 4, 12 and 13 ratings suit indoor and outdoor use
- Compact body 4.01 in high, 1.57 in wide, 2.36 in deep fits tight enclosures
- 1 NC / 1 NO contact form provides both safety and signal circuits
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
How do I mount and adjust the 8.35 in rod on the XCKJ10559H7, and what step is often missed?
Bolt the 1.57 in wide body using the standard mounting pattern, then rotate the rod to the desired trip angle and lock the set screw; the missed step is confirming the 1NC/1NO contacts switch at the exact position before final tightening.
What maintenance or replacement will the XCKJ10559H7 need over time?
Inspect the adjustable rod pivot and 1NC/1NO contact blocks periodically for wear or contamination; replace the complete switch if the NEMA 1, 2, 4, 12, 13 sealing is compromised or contacts no longer carry 10 A at 240 V reliably.
What limit appears first when the XCKJ10559H7 cycles continuously under full 10 A load?
The 10 A at 240 V contact rating is the first constraint; sustained switching at that current accelerates contact erosion and temperature rise inside the 4.01 in high body, so duty cycle must stay within the rated thermal limits.