SQUARE D
SQUARE D HOM2200 HOMELINE 200A 2 Pole 240V circuit breaker
A 200 A two-pole breaker for Homeline load centres, rated 120/240 V AC with a 10 kA interrupting capacity
- Protects heavy 240 V loads with 200 A rating
- Fits Homeline load centres via plug-in mounting
- Interrupts faults up to 10 kA at 120/240 V AC
- Operates reliably from 77 °F minimum temperature
- Compact 5.4 in frame suits standard panel space
SQUARE D HOM2200 200A circuit breaker
The SQUARE D HOM2200 is a 200A two-pole miniature circuit breaker from the HOMELINE series rated for 120/240V AC single-phase supply. It uses a plug-in mounting style designed for Homeline load centres and features a paddle actuator for manual switching. The unit carries a maximum AIR rating of 10kA at 120/240V AC and connects via lug terminals within a 100A/HOM frame size.
Thermal and electrical behaviour
The breaker is rated for a minimum operating temperature of 77 degrees F and has no DC voltage rating. In normal AC operation it carries up to 200A per pole and will interrupt fault currents up to 10kA. The standard paddle actuator gives a clear tactile indication of the on, off and tripped positions without auxiliary contacts or electronic monitoring.
Installation and panel fit
The device measures 5.4 inches long, 4 inches wide and 3 inches deep and plugs directly into compatible Homeline load centres. Lug terminals accept standard copper or aluminium conductors sized for the 200A rating. The two-pole construction occupies two adjacent pole spaces in the panel and provides 240V protection for single-phase branch circuits.
Highlights
- Protects heavy 240 V loads with 200 A rating
- Fits Homeline load centres via plug-in mounting
- Interrupts faults up to 10 kA at 120/240 V AC
- Operates reliably from 77 °F minimum temperature
- Compact 5.4 in frame suits standard panel space
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
How do I plug the HOM2200 into a Homeline load center, and what step do people miss?
Align the paddle actuator with the bus stab, press firmly until the breaker seats fully, then verify the lug terminals are torqued to the panel's specification; the step often missed is confirming the 100A frame size matches the load center's bus rating before energising.
What maintenance or replacement will the HOM2200 need over time?
Periodically inspect the lug connections for discoloration or looseness and exercise the paddle actuator annually; replace the breaker if it trips at or below the 200 A rating or after any fault that approaches the 10kA interrupting limit.
At what sustained load does the HOM2200 reach its thermal limit first?
The breaker is calibrated to carry 200 A continuously at 77 °F ambient; sustained current above that rating or operation in higher ambient temperatures will cause the thermal element to trip before the magnetic 10kA interrupting capacity is tested.