SIEMENS
SIEMENS Emergency Stop Push Button 22mm Red Metal 1NC IP67 IP69K
A 22 mm red metal emergency stop button with 1NC contact, IP67 and IP69K sealing for harsh environments
- Instant emergency stop with maintained action
- 22 mm mounting fits standard panels
- Metal bezel resists impact and corrosion
- IP67 and IP69K seal against water and high-pressure wash
- 1 NC contact rated 10 A at 600 V AC
Emergency Stop Push Button 22mm
This SIEMENS emergency stop push button features a 22mm mounting diameter with a 40mm mushroom head operator. The red plastic head sits in a metal bezel and provides maintained action for safety-critical applications. It carries a single normally closed contact rated at 10A for 600V AC and 1A for 600V DC with NEMA A600/R300 designation.
IP67 IP69K Environmental Protection
The switch meets NEMA ratings 1, 12, 2, 3, 3R, 4, and 4X alongside IP67 and IP69K ingress protection. These ratings confirm resistance to dust, water immersion, and high-pressure washdown environments. Screw terminal connections provide secure wiring for industrial control panels and machinery safety circuits.
REACH WEEE Compliance Included
The device complies with REACH regulation and WEEE directive 2012/19/EU for restricted substances and end-of-life handling. Legend marking reads "Emergency Stop" for clear identification on operator panels. No additional accessories or software are bundled with this standalone safety switch component.
Highlights
- Instant emergency stop with maintained action
- 22 mm mounting fits standard panels
- Metal bezel resists impact and corrosion
- IP67 and IP69K seal against water and high-pressure wash
- 1 NC contact rated 10 A at 600 V AC
Specifications
| Brand | Siemens |
|---|
Questions about this item
How is the 22 mm emergency stop push button mounted, and what step is often missed?
Mount the 22 mm red metal unit in a standard 22 mm panel cut-out, secure the metal bezel with the supplied lock nut, then tighten the screw terminals; the step often missed is torquing the lock nut to prevent rotation under emergency actuation.
What maintenance or replacement will the 1NC contact block need over time?
Inspect the 1NC screw-terminal contact block periodically for carbon tracking or pitting; replace the block if contact resistance rises or after any actuation that exceeds the 10 A 600 V AC / 1 A 600 V DC rating.
Which environmental limit is reached first during continuous exposure to high-pressure wash-down?
The IP69K rating covers high-pressure, high-temperature wash-down, while IP67 covers temporary immersion; the lower-pressure IP67 limit is reached first if the seal degrades and water ingress occurs during immersion.