SIEMENS
SIEMENS B125 Miniature Circuit Breaker BL Series 25A 1 Pole 120/240V AC
A bolt-on miniature circuit breaker rated 25A, single-pole, 120/240V AC with 10kA interrupting capacity for Siemens P1 panelboards
- Reliable overload protection up to 10kA interrupting rating
- Fits standard P1 panelboards with bolt-on mounting
- Single-pole 25A breaker for 120/240V AC circuits
- Accepts 14 AWG copper or 12 AWG aluminium conductors
- Compact 1-inch frame saves space in load centres
Siemens BL Series 25 A Circuit Breaker
This Siemens BL Series miniature circuit breaker provides single-pole overcurrent protection rated at 25 A for 120/240 V AC systems. It features a bolt-on mounting style and toggle actuator designed for use with Siemens P1 panelboards and load centers. The unit carries a maximum AIR rating of 10 kA at the rated voltage.
Electrical panels needing single-pole 25
Installers fitting Siemens P1 series panelboards will find this breaker matches the required form factor and electrical rating. It is not suitable for applications requiring multi-pole switching, DC circuit protection, or plug-in mounting styles. Buyers needing higher interrupting ratings or different frame sizes should select alternative devices.
10 kA AIR rating at 120/240 V AC
The 10 kA interrupting capacity determines whether this breaker can safely clear fault currents in the intended installation. Verify that the available short-circuit current at the panelboard does not exceed this rating. The bolt-on terminal accepts copper wire down to 14 AWG and aluminium wire down to 12 AWG.
Highlights
- Reliable overload protection up to 10kA interrupting rating
- Fits standard P1 panelboards with bolt-on mounting
- Single-pole 25A breaker for 120/240V AC circuits
- Accepts 14 AWG copper or 12 AWG aluminium conductors
- Compact 1-inch frame saves space in load centres
Specifications
| Brand | SIEMENS |
|---|
Questions about this item
Will the 25 A BL series breaker fit in my existing Siemens P1 panelboard?
The breaker is designed for Siemens P1 panelboards and uses a bolt-on mounting style that matches the panelboard bus.
How can I verify the breaker trips correctly after installation?
Turn on the load and confirm the toggle stays in the on position; if an overcurrent occurs the toggle will move to the tripped position.
Does the package include the lug terminals or must I buy them separately?
The breaker comes with integral lug terminals that accept 14 AWG copper or 12 AWG aluminum wire; no separate lugs are needed.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.