Sick
Sick MZC1-2V2PS-KP0 C-slot cylinder sensor PNP 23.7 mm IP68 M8 3-pin 0.3 m
PNP cylinder sensor for C-slot mounting with IP68 rating, 23.7 mm housing and 0.3 m M8 cable
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- PNP output for reliable DC switching
- IP68 enclosure withstands dust and water immersion
- 7 mm housing fits C-slot cylinders
- M8 3-pin connector with 0.3 m PUR cable
- Operates from –30 °C to +80 °C
C-slot cylinder sensor
The Sick MZC1-2V2PS-KP0 is a magnetic proximity switch built for C-slot pneumatic cylinders. It also fits SMC CDQ2 and ECDQ2 rails, round-body cylinders, plus profile and tie-rod cylinders when the appropriate adapter is used. The PNP output makes it compatible with standard 10 V DC to 30 V DC control inputs.
Thermals noise and power
The sensor draws only 8 mA from the supply, keeping heat negligible inside the cable run. Solid-state switching produces no audible noise during operation. An IP68-rated plastic housing and PUR cable withstand wash-down, coolant spray and temporary immersion without degradation.
PNP 1000 Hz switching
The 1,000 Hz switching frequency supports fast cylinder cycles on high-speed packaging or assembly lines. A typical response sensitivity of 2.2 mT and 0.1 mT reproducibility give consistent position feedback. The 0.3 m cable with M8 3-pin connector plugs directly into common I/O blocks.
Highlights
- PNP output for reliable DC switching
- IP68 enclosure withstands dust and water immersion
- 7 mm housing fits C-slot cylinders
- M8 3-pin connector with 0.3 m PUR cable
- Operates from –30 °C to +80 °C
Specifications
| Brand | SICK |
|---|---|
| Model | MZC1-2V2PS-KP0 |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
How do I mount the sensor in a C-slot cylinder and what step is often missed?
Slide the 23.7 mm housing into the C-slot until it seats fully; the step often missed is tightening the set screw to lock the axial position before wiring.
What maintenance or replacement will the M8 cable need over time?
The 0.3 m PUR cable with 0.09 mm² conductors should be inspected for abrasion or connector corrosion; replace the whole sensor if the cable jacket cracks or pins oxidise.
At what temperature does the sensor hit its operating limit first during sustained use?
The ambient operating range tops out at +80 °C; sustained exposure above that temperature will cause the sensor to exceed its rated limit before any other parameter.
Also in this aisle
People compared these