Schneider Electric
Schneider Electric NSYTRV42SF5 Fused Terminal Block 1 Pole 6 A
A fused disconnect terminal block for DIN-rail mounting that accepts 26–10 AWG copper conductors at 6 A and 600 V
- Engine BrandSCHNEIDER ELECTRIC
- Fused disconnect protects circuits up to 6 A
- Screw clamp accepts solid or stranded copper from 26 AWG to 10 AWG
- Two-tier DIN-rail mount saves panel space at 0.32 in wide
- Rated 600 V with CSA, CURus and EAC certifications
- Fits standard 5 mm x 20 mm fuses for quick replacement
Fused Disconnect Terminal Block 6 A
The Schneider Electric NSYTRV42SF5 is a single-pole fused terminal block rated for 6 A and 600 V. It mounts on a standard DIN rail and uses screw-clamp connections for solid or stranded copper wire from 26 AWG to 10 AWG. The black housing holds a 5 mm by 20 mm fuse for circuit protection. It carries CSA, CURus and EAC certifications.
Installers protecting single control circuits
This block suits panel builders who need a compact fuse holder for one 6 A circuit in a DIN-rail enclosure. The two-tier layout keeps wiring tidy while the screw clamps accept a wide wire range. It is not for applications requiring multiple poles in one housing or higher current ratings. Buyers needing fuse sizes other than 5 mm by 20 mm should look elsewhere.
5 mm × 20 mm fuse format decides fit
The terminal block accepts only fuses with a 5 mm diameter and 20 mm length, so the fuse you stock must match those dimensions exactly. A different diameter or length will not seat properly and the circuit will remain unprotected. Verify your fuse specifications before ordering.
Highlights
- Fused disconnect protects circuits up to 6 A
- Screw clamp accepts solid or stranded copper from 26 AWG to 10 AWG
- Two-tier DIN-rail mount saves panel space at 0.32 in wide
- Rated 600 V with CSA, CURus and EAC certifications
- Fits standard 5 mm x 20 mm fuses for quick replacement
Specifications
| Engine Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
Does the block include the 5 mm × 20 mm fuses or must they be purchased separately?
The terminal block accepts 5 mm diameter by 20 mm length fuses; fuses are not included and must be sourced separately.
Should I select the 6 A fused version or a higher-current alternative for a 10 AWG copper circuit?
This model is rated 6 A and accepts wire up to 10 AWG; choose it when the protected circuit requires 6 A or less.
What does the 600 V maximum voltage mean once the block is mounted on a DIN rail?
The 600 V rating is the highest circuit voltage the block’s insulation and fuse holder are certified to withstand when correctly installed.