Schneider Electric
Schneider Electric LC1D09BL 24V DC 9A IEC Contactor Relay
A 24V DC IEC magnetic contactor rated for 9A inductive and 25A resistive loads with 1NO/1NC auxiliary contacts
- 9 A inductive rating handles motor loads reliably
- 25 A resistive capacity supports heating circuits directly
- 24 V DC coil operates from standard control supplies
- 3 poles plus 1 NO/1 NC auxiliary cover power and signal needs
- UL, CSA, IEC and EN listings simplify compliance paperwork
24V DC 9A IEC Contactor
This Schneider Electric LC1D09BL contactor switches inductive loads up to 9 A and resistive loads up to 25 A at 24 V DC coil voltage. It provides three main poles plus one normally open and one normally closed auxiliary contact for control circuits. The unit conforms to UL, CSA, IEC and EN standards and carries no integral enclosure. It suits panel builders and OEMs assembling motor starters or lighting panels.
Industrial motor and lighting control panels
The contactor fits three-phase motor circuits rated 2 hp at 208 V or 240 V, 5 hp at 480 V and 7 1/2 hp at 575 V, plus single-phase duties up to 1 hp at 240 V. Installers needing a reversing starter or a higher inductive current rating should select a different model. Applications requiring a built-in enclosure or a coil voltage other than 24 V DC will not be served by this unit.
9 A inductive, 25 A resistive headroom
The 9 A inductive rating comfortably handles small compressors, pumps and fan motors within the listed horsepower limits. Resistive heating loads up to 25 A are supported for lighting banks or heater elements. Operation at 50 Hz or 60 Hz is covered, but loads exceeding the 9 A inductive or 25 A resistive limits will require a larger frame contactor.
Highlights
- 9 A inductive rating handles motor loads reliably
- 25 A resistive capacity supports heating circuits directly
- 24 V DC coil operates from standard control supplies
- 3 poles plus 1 NO/1 NC auxiliary cover power and signal needs
- UL, CSA, IEC and EN listings simplify compliance paperwork
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
What coil voltage must the control circuit supply for this LC1D09BL contactor?
The coil operates at 24 V DC, so the control circuit must provide a stable 24 V DC source.
Can this 9 A inductive-rated contactor directly switch a 25 A resistive load such as heating elements?
Yes, the resistive full-load rating is 25 A, which is separate from the 9 A inductive rating.
How can I verify the contactor is operating correctly after wiring the 1NO/1NC auxiliary contacts?
Measure continuity on the auxiliary contacts — 1NO should close and 1NC should open when the 24 V DC coil is energised.