Schneider Electric
Schneider Electric GV2ME03 Manual Motor Starter 3P 0.4A IP20 video accessory
A manual motor starter with three poles, 0.4 A thermal overload protection and IP20 rating for 690 V AC circuits
- TypeIndustrial Electrical Controls & Automation
- Colordark grey
- Manual motor starter rated for 690V AC three-phase supply
- Thermal overload protection adjustable from 0.25 A to 0.4 A
- Three-pole screw clamp terminals simplify wiring
- IP20 enclosure rating protects against solid objects
- Fire-resistant housing meets industrial safety requirements
Schneider Electric GV2ME03 Motor Starter
The Schneider Electric GV2ME03 is a three-pole manual motor starter rated at 0.4 A with a thermal overload range of 0.25 A to 0.4 A. It operates at up to 690 V AC on 50/60 Hz supplies and carries an IP20 rating. The unit uses screw-clamp terminals and a push-button operator in a dark grey housing.
Replaces older IEC starters lacking 690 V rating
This starter upgrades installations that previously used lower-voltage IEC devices or starters without adjustable thermal protection. The jump is worth it when the application demands a 3 A pole count at 690 V AC and a precise 0.25 A to 0.4 A setting range. It suits panels moving from fixed-trip to adjustable overload schemes.
Check panel depth and wiring before ordering
Verify that the 3.09 in overall depth fits your enclosure and that screw-clamp terminals match your conductor size. Confirm the supply is three-phase 50/60 Hz and that IP20 protection meets the environmental requirements. The starter has no built-in enclosure, so a separate IP-rated box may be needed.
Highlights
- Manual motor starter rated for 690V AC three-phase supply
- Thermal overload protection adjustable from 0.25 A to 0.4 A
- Three-pole screw clamp terminals simplify wiring
- IP20 enclosure rating protects against solid objects
- Fire-resistant housing meets industrial safety requirements
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | dark grey |
Questions about this item
What depth clearance does the 3.09 in. starter need inside the enclosure?
The unit measures 3.09 in. overall depth, so allow at least that much space behind the mounting rail plus room for screw-clamp wiring.
How do I connect the three phases to the screw-clamp terminals without a loose strand?
Strip each conductor to the recommended length, insert fully into the screw clamp, and tighten until the insulation touches the terminal body — no ferrule crimping is required.
When should the thermal overload on this 0.4 A starter be checked or replaced?
Inspect the thermal element after any trip event; if it will not hold between the 0.25 A minimum and 0.4 A maximum settings, replace the starter.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.