We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Schneider Electric
Variable frequency drive for three-phase motors, 2 HP at 230 VAC with 0.5–400 Hz output range and NEMA 1 enclosure
The Schneider Electric Altivar unit is a variable frequency drive rated for two horsepower at 230 volts AC three-phase input. It accepts supply voltages from 200 to 240 volts at 50 or 60 hertz and delivers three-phase output adjustable from 0.5 up to 400 hertz. The enclosure carries a NEMA 1 rating for indoor mounting. This drive suits engineers and maintenance teams automating pumps, fans or conveyors in commercial and light-industrial buildings.
Continuous output current reaches 7.5 amperes within the stated voltage range. The drive converts incoming three-phase mains to a variable-frequency output without requiring external line reactors for typical installations. Heat generated during normal operation is dissipated through the integral heatsink and convection airflow inside the NEMA 1 housing. Audible noise remains limited to the internal cooling fan and magnetostriction in the output stage under load.
The NEMA 1 enclosure provides finger-safe terminal access and knockouts for conduit entry at the bottom. Three-phase input and output terminals accept standard building cable sizes used in 200 to 240 volt industrial wiring. Control terminals are grouped separately for start, stop, speed reference and safety interlock signals. The unit mounts vertically on a flat panel using four fixing points, leaving clearance above and below for natural convection.
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Building Cable |
Connect L1, L2, L3 to the supply and the motor to U, V, W; the step often missed is verifying the motor rotation direction before commissioning.
The internal cooling fan and electrolytic capacitors on the DC bus typically require replacement after several years of sustained 7.5 A output.
The drive reaches its maximum programmable output frequency of 400 Hz, which is the first limit encountered during sustained high-speed operation.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?