Schneider Electric
Schneider Electric 9001KYG1Y1 30 mm Emergency Stop Station 1NC
A wall-mounted 30 mm emergency stop station with a red mushroom head, 1NC contact, IP66 and NEMA 4 zinc enclosure in yellow
- Engine BrandSCHNEIDER ELECTRIC
- Engine Size30 mm
- Red mushroom head enables fast emergency shutdown
- Maintained action stays latched until manually reset
- 1NC contact rated 10A at 600V AC and 2.5A at 24V DC
- IP66 and NEMA 4 enclosure resists dust and water ingress
- Zinc housing with 3/4 in NPT hub suits wall mounting
Emergency Stop Station 30 mm
The Schneider Electric 9001KYG1Y1 is a wall-mount control station built for industrial safety circuits. A single red mushroom-head push button provides maintained emergency-stop action with one normally-closed contact.
Contact Rating 10A 600V AC
The 1NC contact handles 10 A at 600 V AC or 2.5 A at 24 V DC, meeting A600/Q600 designation. It suits standard three-phase motor starters and control relays but lacks the capacity for high-current direct motor switching.
IP66 Zinc Enclosure 3/4 NPT
The yellow zinc housing rated IP66 and NEMA 4 resists water jets and dust in wash-down environments. A 3/4 inch NPT hub allows rigid conduit entry, while the 30 mm operator cut-out matches standard panel layouts.
Highlights
- Red mushroom head enables fast emergency shutdown
- Maintained action stays latched until manually reset
- 1NC contact rated 10A at 600V AC and 2.5A at 24V DC
- IP66 and NEMA 4 enclosure resists dust and water ingress
- Zinc housing with 3/4 in NPT hub suits wall mounting
Specifications
| Engine Brand | SCHNEIDER ELECTRIC |
|---|---|
| Engine Size | 30 mm |
Questions about this item
Will the 30 mm mushroom-head button fit the existing 30 mm panel cut-out on my older control panel?
Yes — the operator is a 30 mm push-button with mushroom head, matching the standard 30 mm mounting hole used on legacy panels.
How can I verify the 1NC contact opens correctly when I press the emergency-stop button?
With power off, measure continuity across the contact terminals; the circuit should be closed until the red mushroom head is pressed, then open and stay open until the head is twisted or pulled to reset.
Does the yellow zinc enclosure come with the 3/4 in NPT hub fitted, or must I supply my own conduit fitting?
The station includes a 3/4 in NPT hub already threaded into the zinc enclosure; no separate conduit fitting is required for wall mounting.