Ruth's sister
Ruth's sister YM-2451C 450W redundant hot-swap server power supply
A 450 W redundant hot-swap server power supply with active PFC and 100-264 V input
- 450 W output powers demanding server workloads
- Redundant hot-swap design keeps systems running during module replacement
- Active PFC improves power factor and efficiency
- Wide 100–264 V input suits global rack deployments
- SSI R512 G2 form factor fits standard server chassis
450W Redundant Hot-Swap Server PSU
This 450 watt server power supply uses an SSI form factor with active PFC and a 100-264 volt input range. It supports redundant hot-swap operation so a failed unit can be replaced without shutting down the system. The non-modular design keeps cabling fixed for dense chassis layouts.
Upgrade from single non-hot-swap units
Moving from a single fixed supply to this redundant hot-swap module adds continuous uptime during maintenance or failure events. The jump is worth it when the chassis accepts SSI R512 G2 modules and the workload cannot tolerate a power-cycle to swap a supply.
Suits rack servers needing 450W redundancy
Operators running compatible SSI bays who need 450 watts per module with hot-swap redundancy will fit this unit directly. Builders using ATX or EPS bays, or systems requiring modular cables or 12 volt GPU connectors, should look at other form factors.
Highlights
- 450 W output powers demanding server workloads
- Redundant hot-swap design keeps systems running during module replacement
- Active PFC improves power factor and efficiency
- Wide 100–264 V input suits global rack deployments
- SSI R512 G2 form factor fits standard server chassis
Specifications
No published specifications for this item yet.
Questions about this item
What chassis form factor does the YM-2451C redundant hot-swap supply fit?
The YM-2451C follows the SSI Power R512 G2 footprint, so it mounts in any server bay designed for that standard redundant form factor.
How is the YM-2451C installed, and what step is often missed?
Slide the unit into the hot-swap bay until the latch clicks; the step often missed is verifying the latch is fully seated so the AC inlet engages the chassis bus.
Which component of the YM-2451C will need replacement first in continuous use?
The internal 12 V cooling fan is the primary wear item; plan to swap it when bearing noise appears, typically after several years of 24/7 operation.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Sunfounder Raspberry Pi Ultimate Kit with PiCrawler AI Robot 337 components 131 projects
minisforum MF-SRP01 SSD Heatsink accessories barebone
- SSD Heatsink



