REED INSTRUMENTS
REED INSTRUMENTS TP-01-NIST Beaded Thermocouple Wire Probe, Type K
Type K beaded thermocouple wire probe with NIST certification measures from -40 to 482 degrees
- ColorTransparent
- NIST calibration ensures traceable accuracy
- Type K thermocouple covers -40 to 482 °F range
- Beaded wire design enables fast thermal response
- Transparent insulation allows visual wire inspection
- REED INSTRUMENTS quality for reliable temperature measurement
Type K thermocouple probe with NIST certification
This REED INSTRUMENTS TP-01-NIST beaded wire probe is a Type K thermocouple supplied new with NIST traceable certification. It suits HVAC technicians, laboratory staff and calibration engineers who need documented measurement accuracy from a trusted brand. The transparent insulation allows quick visual inspection of the bead junction.
Measurement range from -40 to 482
The single specification that decides fit is the operating window of -40 to 482. Any application that stays inside this span can use the probe; any process that exceeds either limit cannot. No other range or sensor type is offered for this model.
Beaded junction responds quickly under steady
The exposed bead construction gives fast thermal equilibrium when the probe is held in a stable air or fluid stream. Under sustained load the thin wires reach temperature rapidly and maintain consistent output without the lag of sheathed alternatives. The transparent insulation remains intact across the full certified range.
Highlights
- NIST calibration ensures traceable accuracy
- Type K thermocouple covers -40 to 482 °F range
- Beaded wire design enables fast thermal response
- Transparent insulation allows visual wire inspection
- REED INSTRUMENTS quality for reliable temperature measurement
Specifications
| Brand | REED INSTRUMENTS |
|---|---|
| Color | Transparent |
Questions about this item
What does the -40 to 482 temperature range mean for everyday HVAC measurements?
The probe reads from minus 40 up to 482, so it covers frozen coils, room air and hot discharge lines in one tool.
How does the Type K interface limit what meters I can plug it into?
Any meter or logger with a Type K input accepts the connector; the thermocouple physics set the accuracy, not the jack.
What does the transparent insulation tell me about routing the bead through a duct or panel?
The clear jacket lets you see the bead position while feeding it through tight openings or around bends.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.