Red Hat 8262H013V Solenoid Valve 1/4 in NPTF 120V AC 6.1W
Direct-acting, normally closed solenoid valve controls air, inert gas, light oil and water with a brass body, FKM seals, 1/4 in NPTF ports and 120 V AC coil
- TypeDrain Components
- Direct-acting design enables fast response with 0.73 Cv flow
- Normally closed operation stops flow when de-energised for safety
- Brass body with FKM seals handles air, oil and water up to 180°F
- NEMA 4X watertight coil resists harsh industrial environments
- 120 V AC 6.1 W coil with 18 in leads simplifies wiring
1/4 in NPTF solenoid valve
The Red Hat 8262H013V is a direct-acting, normally closed 2-way solenoid valve with a brass body and FKM seals. It controls air, inert gas, light oil, or water in industrial piping systems. The coil operates on 120V AC at 60 Hz and draws 6.1 W. NEMA 1, 2, 3, 3S, 4, and 4X enclosure ratings suit wet or dusty environments.
Suitable applications and limits
This valve suits automated drain or trap lines that need a compact 1/4 in NPTF connection and a Cv of .73. Buyers who need a larger flow path, a different voltage, or a normally open default should look at other models. It is not for fluids hotter than 180°F or ambient conditions above 131°F.
Maximum pressure differential
The pressure differential limit decides if this valve fits the circuit: 55 psi for air or inert gas, 40 psi for light oil, and 54 psi for water. Exceeding these values will prevent reliable shut-off. Check the system pressure against the fluid you are controlling before ordering.
Highlights
- Direct-acting design enables fast response with 0.73 Cv flow
- Normally closed operation stops flow when de-energised for safety
- Brass body with FKM seals handles air, oil and water up to 180°F
- NEMA 4X watertight coil resists harsh industrial environments
- 120 V AC 6.1 W coil with 18 in leads simplifies wiring
Specifications
| Type | Drain Components |
|---|---|
| Brand | Red Hat |
| Model | 8262H013V |
Questions about this item
Should I choose the 1/4 in NPTF version or look for a different pipe size?
This model has a 1/4 in NPTF thread on both inlet and outlet. Select it when your piping uses the same size and thread standard.
What does the 6.1 W coil rating tell me about power draw once installed?
The coil draws 6.1 W at 120 V AC 60 Hz, so the valve adds a small, steady load to the control circuit.
How do the NEMA 1, 2, 3, 3S, 4, 4X ratings limit where I can mount the valve?
The watertight coil enclosure meets NEMA 1, 2, 3, 3S, 4 and 4X, allowing indoor and outdoor use with protection against water, dust and corrosion.