Red Hat
Red Hat 238614-132-D* Solenoid Valve Coil 120VAC 60Hz 17.1W
Solenoid valve coil rated 120 VAC at 60 Hz with 17.1 W power, Class F insulation, 18 in leads, NEMA 7 and 9 enclosure, UL listed, compatible with EF8320G192 and EF8320G200 models
- TypeDrain Components
- MaterialHAWA
- Hazardous-location rated coil meets NEMA 7 and 9 standards
- UL Listed for verified safety compliance
- Class F insulation handles 17.1 W continuous power
- 18-inch leads simplify wiring in tight spaces
- Compatible with EF8320G192 and EF8320G200 valve models
Coil for hazardous-location drains
The Red Hat 238614-132-D* solenoid valve coil operates on 120 VAC at 60 Hz and draws 17.1 W. It is built for drain and trap assemblies that require a NEMA 7 and 9 rated enclosure without a junction box. Class F insulation and 18-inch leads complete the package. UL listing confirms compliance for hazardous-area installations.
Direct replacement for EF8320G series valves
This coil matches manufacturer models EF8320G192-120/60 110/50 and EF8320G200-120/60 110/50. The swap is worthwhile when an existing coil shows insulation breakdown or when the enclosure rating must meet Class I Division 1 and Class II Division 1 requirements. No wiring changes are needed because the lead length and voltage rating remain identical.
Handles 17.1 W continuous with 93 VA inrush
Holding current sits at 40 VA while inrush peaks at 93 VA, giving enough magnetic force for reliable actuation in drainage service. The design runs out of headroom if system voltage drifts far above 120 VAC or if ambient temperature exceeds the Class F limit, so verify supply stability before installing.
Highlights
- Hazardous-location rated coil meets NEMA 7 and 9 standards
- UL Listed for verified safety compliance
- Class F insulation handles 17.1 W continuous power
- 18-inch leads simplify wiring in tight spaces
- Compatible with EF8320G192 and EF8320G200 valve models
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Red Hat |
| Model | 238614-132-D* |
Questions about this item
What length leads does the Red Hat 238614-132-D* coil have for electrical connections?
The coil is supplied with 18 in. leads for wiring into the circuit.
How is the coil mounted, and what common mistake should be avoided?
It fits compatible ASCO valve bodies such as EF8320G192 or EF8320G200; the error is forcing it onto a non-listed model.
What ongoing checks does this hazardous-location coil require?
Inspect the Class F insulation and 18 in. leads periodically for heat damage or wear, and verify the NEMA 7 and 9 enclosure seal remains intact.