Philips
Philips MSR Gold 700/2 FastFit DLP Replacement Lamp for D.T.S. XR2000 SPOT BEAM
A 700 W DLP replacement lamp delivering 50 000 lm at 7 500 K with FastFit installation for the D.T.S. XR2000 SPOT BEAM
- TypeProject Lamp
- Weight0.1000
- Bright 50,000 lm output for large venues
- 7,500 K colour temperature for crisp white light
- FastFit design enables quick lamp changes
- 700 W rated power with 71 lm/W efficacy
- CRI 75 maintains colour accuracy over time
Philips MSR Gold 700/2 FastFit Lamp
This replacement lamp is designed specifically for the D.T.S. XR2000 SPOT BEAM projector. It serves venues and technicians who need a direct-fit light source for that fixture. The lamp arrives new and ready for installation in compatible entertainment or architectural lighting setups.
FastFit Base and Thermal Limits
The FastFit base allows quick lamp changes without tools during maintenance windows. Operating limits show a maximum bulb temperature of 950 C and a maximum pinch temperature of 500 C, so adequate fixture ventilation is essential for reliable service life. Ignition requires a minimum supply voltage of 198 V.
700 W Output and Colour Metrics
Rated power is 700 W with a nominal lamp current of 10.2 A. Initial lumen output reaches a nominal 50000 lm at a correlated colour temperature of 7500 K. The colour rendering index is 75 and luminous efficacy is 71 lm/W, defining the brightness and colour quality delivered.
Highlights
- Bright 50,000 lm output for large venues
- 7,500 K colour temperature for crisp white light
- FastFit design enables quick lamp changes
- 700 W rated power with 71 lm/W efficacy
- CRI 75 maintains colour accuracy over time
Specifications
| Brand | Jaspertronics |
|---|---|
| Model | D.T.S. XR2000 SPOT BEAM-LAMP |
| Part Number | D.T.S. XR2000 SPOT BEAM-LAMP |
| Type | Project Lamp |
| Weight | 0.1000 |
Questions about this item
What power and voltage does the MSR Gold 700/2 FastFit lamp require?
It is rated at 700 W with a nominal lamp current of 10.2 A and needs a minimum ignition supply voltage of 198 V.
What physical clearances must the fixture allow for the lamp's operating temperatures?
The bulb temperature can reach 950 °C and the pinch temperature 500 °C, so the housing must tolerate those peaks.
How is the FastFit lamp installed, and what alignment step is critical?
The FastFit base is inserted and locked with a quarter-turn; the critical step is seating the pins fully before turning so the lamp aligns with the optical axis.