Parker BF-164S Bi-Flow Dryer 1/2 In Sweat
Liquid-line filter dryer with bi-flow operation for heat-pump systems using CFC, HCFC and HFC refrigerants
- Bi-flow design enables heat-pump operation
- 8-ton capacity supports R-22 and R-410A systems
- 1/2-inch sweat connection simplifies copper piping
- Steel shell resists high-side pressure cycles
- 6 1/16-inch overall length fits standard liquid-line layouts
Parker BF-164S Bi-Flow Dryer
The Parker BF-164S is a liquid line filter dryer designed for heat pump applications. It suits HVAC technicians servicing residential or light commercial systems that require bi-directional flow capability. The unit filters moisture and contaminants from refrigerant circuits during normal and reverse-cycle operation. It is not intended for large-capacity commercial chillers or industrial process cooling systems.
Sweat Connection Constraints
The 1/2 inch sweat connection requires brazing during installation, which demands appropriate torch equipment and nitrogen purge practices. The 6 1/16 inch overall length and 5 1/16 inch cut-out length define the fixed space needed in the liquid line. Systems using refrigerants outside the CFC, HCFC and HFC families cannot use this dryer. The 8 ton capacity rating for both R-22 and R-410A sets the maximum system size.
Installation Notes
Copper-to-copper brazing with phosphorus-bearing alloy is standard for the sweat fittings; flux is not required but nitrogen flow prevents internal oxidation. The steel shell must be protected from excessive heat during brazing to avoid damaging internal desiccant cores. Flow direction arrows must match the heat pump's cooling mode refrigerant path. Overheating the body or reversing the flow orientation are the most common field errors.
Highlights
- Bi-flow design enables heat-pump operation
- 8-ton capacity supports R-22 and R-410A systems
- 1/2-inch sweat connection simplifies copper piping
- Steel shell resists high-side pressure cycles
- 6 1/16-inch overall length fits standard liquid-line layouts
Specifications
| Brand | PARKER |
|---|
Questions about this item
Should I choose the BF-164S or a different capacity for my heat pump?
The BF-164S handles 8 ton on both R-22 and R-410A, so select it when your system falls at or below that capacity.
What does the 8 ton rating mean once the dryer is installed?
It indicates the maximum cooling capacity the dryer can protect while maintaining proper moisture removal on R-22 or R-410A.
How does the 1/2 inch sweat connection affect installation?
The 1/2 inch solder connection requires brazing into the liquid line, giving a permanent, leak-free joint for bi-flow heat pump operation.
More in HVAC Controls
Similar items
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Mroinge M721 Non-Programmable Heat Pump HVAC Control 2H/1C 24V 12 Pack
- Temperature Sensor,…
- 0.99 in x 4.92 in x…
Gree Electric 27210071 hvac control remote holder grey
- HVAC Controls
Suuwer S701 Non-Programmable Thermostat 1H/1C Blue Backlight 12 Pack
- Suuwer Thermostat,…
- 4.72 in x 0.98 in x…
Suuwer S701 Non-Programmable Thermostat Green Backlight
- Suuwer Thermostat,…
- 0.98 in x 4.72 in x…