Panduit Ring Terminal Bare #10 8 AWG PK200
Bare copper ring terminal for 8 AWG wire, #10 stud, brazed seam, 1.14 in. long, rated 302 °F and 2,000 V, UL and CSA listed, pack of 200
- MaterialHAWA
- Bare copper terminal crimps securely to 8 AWG wire
- Brazed seam resists separation under vibration and load
- Rated 2,000 V and 302 °F for demanding circuits
- #10 stud hole fits common automotive and panel hardware
- CSA C22.2 No. 65 and UL 486A-486B listed for code compliance
8 AWG Ring Terminals for #10 Studs
These bare copper ring terminals accept 8 AWG wire and fit a #10 stud for secure crimp connections. The pack contains 200 pieces suited to automotive, industrial and panel-building work where reliable terminations are required.
302 °F Rating and 2 000 V Maximum
Brazed-seam construction and copper material support continuous operation up to 302 degrees Fahrenheit and a maximum voltage of 2 000 V. The bare finish avoids insulation bulk while maintaining conductivity in high-temperature environments.
CSA and UL Listed for Code Compliance
Terminals meet CSA C 22.2 No. 65 and UL 486A-486B standards, simplifying inspection approvals. The 0.47 inch tongue width and 1.14 inch overall length fit standard #10 hardware without modification.
Highlights
- Bare copper terminal crimps securely to 8 AWG wire
- Brazed seam resists separation under vibration and load
- Rated 2,000 V and 302 °F for demanding circuits
- #10 stud hole fits common automotive and panel hardware
- CSA C22.2 No. 65 and UL 486A-486B listed for code compliance
Specifications
| Brand | Panduit |
|---|---|
| Material | HAWA |
Questions about this item
How do I crimp the 8 AWG wire into the Panduit ring terminal and what step is often missed?
Strip the insulation to expose the copper, insert the wire fully into the barrel, then use a ratchet crimp tool calibrated for 8 AWG; the step often missed is verifying the crimp with a go/no-go gauge before heat-shrinking.
What maintenance or replacement will the Panduit ring terminal need over time?
The bare copper terminal with brazed seam requires no scheduled maintenance; inspect for corrosion or mechanical loosening at each service interval and replace only if the crimp shows damage or the connection becomes resistive.
What is the first limit reached on the Panduit ring terminal under sustained load?
The 302 °F maximum temperature rating is the first limit reached under sustained current; the 2,000 V insulation rating and CSA C22.2 No. 65 / UL 486A-486B compliance provide higher margins.