Panduit
Panduit PN18-6R-C Ring Terminal Nylon Insulated 22 to 18 AWG #6 Stud Red 100 Pack
Nylon-insulated ring terminals accept 22-18 AWG wire onto a #6 stud, rated 600 V and 221 °F, 100 per pack
- MaterialHAWA
- Connects 22 to 18 AWG wires securely
- Nylon insulation withstands 221 Degrees F heat
- #6 stud size fits common terminal blocks
- CSA and UL certified for 600 V safety
- 100 terminals per pack for volume jobs
Panduit PN18-6R-C Ring Terminals 100 Pack
These Panduit PN18-6R-C ring terminals come in a 100-piece pack for electrical wiring jobs. Each terminal accepts 22 to 18 AWG wire and fits a #6 stud. The nylon insulation is rated to 221 degrees F and 600 V maximum. They meet CSA C 22.2 No. 65, MS25036-102 and UL 486A-486B standards.
Suited for small-gauge crimp connections on #6 studs
Electricians and technicians making copper crimp connections on #6 studs with 22 to 18 AWG wire will find these terminals match the spec. The red nylon insulation provides a clear visual identifier. Builders who need a larger stud size, a different wire gauge range or a non-insulated terminal should look at other options.
#6 stud size with 22 to 18 AWG wire range
The critical specification is the #6 stud size combined with the 22 to 18 AWG wire range. This pairing decides whether the terminal fits the stud and accepts the conductor. The 0.25 in tongue width and 0.79 in overall length follow from that specification.
Highlights
- Connects 22 to 18 AWG wires securely
- Nylon insulation withstands 221 Degrees F heat
- #6 stud size fits common terminal blocks
- CSA and UL certified for 600 V safety
- 100 terminals per pack for volume jobs
Specifications
| Brand | Panduit |
|---|---|
| Material | HAWA |
Questions about this item
How do I crimp the Panduit PN18-6R-C ring terminal onto 22 to 18 AWG wire, and what is the common mistake?
Strip the wire to the correct length, insert fully into the barrel, and crimp with a tool rated for 22 to 18 AWG. The frequent error is leaving wire strands exposed outside the crimp or using an oversized die, which weakens the connection.
Will the nylon insulation on these terminals degrade and need replacement over time?
The nylon insulation is rated to 221 degrees F. In normal environments it lasts the life of the connection; replacement is only needed if the insulation is cracked, melted, or the crimp shows corrosion.
At what current or temperature limit does the terminal reach its maximum rating first during sustained use?
The terminal is rated for 600 V and a maximum temperature of 221 degrees F. Under sustained load, the temperature limit is typically reached before the voltage limit becomes a factor.