Panduit
Panduit F85-18-C Ferrule 4 AWG Non-Insul 23/32in PK100
Tin-plated copper ferrule for 4 AWG wire, 23/32 in. insertion length, CSA and DIN compliant, pack of 100
- Tin-plated copper barrel resists corrosion for lasting conductivity
- 23/32 inch insertion length ensures secure wire seating in terminals
- Rated to 302 °F for reliable performance in high-heat environments
- Meets CSA C22.2 No. 291-14 and DIN 46228 Part 1 standards for code compliance
- Pack of 100 ferrules supplies volume for large wiring jobs
Panduit 4 AWG Non-Insulated Ferrule
The Panduit F85-18-C is a bare copper wire ferrule with a tin-plated finish. It accepts a single 4 AWG conductor and has an insertion length of 23/32 in. The barrel diameter measures 0.3 in. Each pack contains one hundred pieces for high-volume electrical termination work.
Suited for panel builders using 4 AWG copper wire
Installers who need an insulated sleeve or a different wire gauge should select another part. This ferrule has no insulation material and is sized only for the stated conductor. Buyers requiring a colour-coded insulator or a multi-size assortment will not find those features here.
Tin-plated copper barrel meets CSA and DIN standards
The contact material is copper with a tin finish rated to a maximum operating temperature of 302 Degrees F. Compliance includes CSA C 22.2 No. 291-14 and DIN 46228 Part 1. This certification profile determines whether the component satisfies the approval requirements for a given project.
Highlights
- Tin-plated copper barrel resists corrosion for lasting conductivity
- 23/32 inch insertion length ensures secure wire seating in terminals
- Rated to 302 °F for reliable performance in high-heat environments
- Meets CSA C22.2 No. 291-14 and DIN 46228 Part 1 standards for code compliance
- Pack of 100 ferrules supplies volume for large wiring jobs
Specifications
| Brand | PANDUIT |
|---|
Questions about this item
What does the 23/32in insertion length mean when I crimp this ferrule onto a 4 AWG wire?
The 23/32in insertion length is the distance the stripped wire must enter the barrel so the crimp covers the full copper barrel and meets the CSA C 22.2 No. 291-14 and DIN 46228 Part 1 standards.
How does the tin-plated copper barrel affect the connection standard for a 4 AWG conductor?
The tin-plated copper barrel meets CSA C 22.2 No. 291-14 and DIN 46228 Part 1 for 4 AWG wire, providing corrosion resistance and a gas-tight crimp at up to 302 Degrees F.
What tool or die do I need to fit the 0.3in barrel diameter on a 4 AWG wire?
Use a crimp tool matched to 4 AWG non-insulated ferrules with a 0.3in barrel diameter; the compatible manufacturer model number is CT-1005.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.