OEM Industries
OEM Industries RS15 KTK KLM 5A 500/690V 10x38mm ceramic fuse box of 20
Box of 20 fast-blow 5 A ceramic tube fuses rated 500/690 V, 10 × 38 mm
- TypeCircuit Protectors
- Selling UnitBox
- Amps5
- 20 fuses per box for convenient stockholding
- 5 A fast-blow rating protects circuits quickly
- 500/690 V AC rating suits high-voltage systems
- 100/50 kA breaking capacity handles large fault currents
- 10 × 38 mm ceramic tube fits standard holders
Circuit protection for industrial circuits
This box supplies twenty fast-blow cylindrical ceramic fuses rated at 5 A for 500/690 V circuits. They suit maintenance engineers and panel builders who need reliable short-circuit protection in automation, generator or distribution equipment. Each fuse carries the RS15 KTK KLM designation and fits standard 10 x 38 mm holders.
Thermal behaviour in normal service
The ceramic tube construction dissipates heat evenly during continuous operation at rated current. Fast-blow characteristics limit let-through energy so downstream components stay cool under everyday loads. Rated breaking capacity reaches 100 kA at 500 V and 50 kA at 690 V, keeping temperature rise minimal in typical panels.
Performance under sustained overload
Under prolonged overcurrent the element melts quickly to interrupt the circuit before wiring insulation degrades. High rupturing capacity ensures safe clearance even during severe fault conditions without case rupture. The 20-piece box supports scheduled replacement programmes for critical infrastructure.
Highlights
- 20 fuses per box for convenient stockholding
- 5 A fast-blow rating protects circuits quickly
- 500/690 V AC rating suits high-voltage systems
- 100/50 kA breaking capacity handles large fault currents
- 10 × 38 mm ceramic tube fits standard holders
Specifications
| Model | RS15 KTK KLM |
|---|---|
| Type | Circuit Protectors |
| Selling Unit | Box |
| Amps | 5 |
Questions about this item
How do I install these 10x38mm ceramic fuses and what step is often missed?
Insert each fuse into a compatible 10x38mm holder until fully seated; the step often missed is verifying the holder voltage rating covers 690 V AC and that the circuit prospective short-circuit current does not exceed 100 kA.
What maintenance or replacement will these fast-blow fuses need later?
No routine maintenance is required; after any over-current event the fuse element opens permanently, so replace the blown unit with an identical 5 A aR RS15 KTK KLM fuse from the same box.
What limit appears first under sustained use at the rated 5 A?
The fuse is designed to carry 5 A continuously; the first limit under sustained load is the 500 V AC / 690 V AC rated voltage — exceeding it risks insulation breakdown before the 100 kA interrupting capacity is reached.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.