OEM Industries
OEM Industries RO15 32A gG 500/690V 50kA Ø10*38mm Ceramic Fuse Box of 20
Box of 20 cylindrical ceramic fuses rated 32 A, 500/690 V with 50 kA breaking capacity
- TypeCircuit Protectors
- Selling UnitBox
- Amps32
- Ready for immediate installation with 20 fuses per box
- Protects circuits up to 32 A with gG characteristic
- Withstands 50 kA short-circuit current at 500/690 V
- Standard 10 x 38 mm ceramic body fits common holders
- Cross-references RT18-32, RT14-20, RT19-25 and gF2 types
RO15 32A gG ceramic fuse box
This box contains twenty RO15 32A gG cylindrical ceramic tube fuses rated at 500/690V with a 50kA breaking capacity. They are designed for line protection in generators and electrical supply circuits where this voltage and fault rating are required. Each fuse measures Ø10*38mm and carries the cross-references RT18-32, RT14-20, RT19-25 and gF2.
Electrical maintenance teams and panel builders
Suited for professionals replacing gG-class fuses in existing holders that accept Ø10*38mm cylindrical bodies at 32A. Not for installers who need a different ampere rating, a different body size, or a fuse class other than gG for the same circuit.
500/690V 50kA rating in a Ø10*38mm body
The voltage and breaking-capacity combination printed on each fuse is the single specification that determines whether the part matches the protection requirements of the circuit. Verify this rating against the system design before fitting.
Highlights
- Ready for immediate installation with 20 fuses per box
- Protects circuits up to 32 A with gG characteristic
- Withstands 50 kA short-circuit current at 500/690 V
- Standard 10 x 38 mm ceramic body fits common holders
- Cross-references RT18-32, RT14-20, RT19-25 and gF2 types
Specifications
| Model | RO15 RT18-32 RT14-20 RT19-25 gF2 |
|---|---|
| Type | Circuit Protectors |
| Selling Unit | Box |
| Amps | 32 |
Questions about this item
Which cross-reference model should I pick — RT18-32, RT14-20 or RT19-25?
All three cross-references map to the same 32 A gG ceramic fuse; the box contains 20 identical pieces rated for 500/690 V and 50 kA breaking capacity.
What does the 50 kA rating mean when the fuse is installed in a panel?
It guarantees the fuse can safely interrupt a prospective short-circuit current of up to 50 kA without rupturing the ceramic body.
Will the Ø10×38 mm size fit a standard 10×38 mm fuse holder?
Yes — the 10 mm diameter and 38 mm length match the industry-standard 10×38 mm cylindrical holder used in many industrial panels.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.