OEM Industries
OEM Industries RO15 2A gG 500/690V 50kA Ø10×38mm Cylindric Fuse Box of 20
Box of 20 cylindrical fuses rated 2 A, 500/690 V and 50 kA breaking capacity in 10×38 mm size
- TypeCircuit Protectors
- Selling UnitBox
- Amps2
- Box of 20 fuses simplifies stock management
- 2 A rating protects low-current circuits reliably
- gG class clears general-purpose overloads cleanly
- 500/690 V rating suits industrial voltage levels
- 50 kA breaking capacity handles severe fault currents
Cylindrical fuse for circuit protection
The OEM Industries RO15 2A gG fuse provides line protection at a rated current of 2 amps. Each box contains 20 pieces suitable for industrial and commercial electrical installations. The cylindrical body fits Ø10×38mm fuse holders commonly used in control panels and distribution boards.
Rated voltage and breaking capacity
These fuses operate at 500/690V AC with a high breaking capacity of 50kA. The gG characteristic ensures reliable operation for general-purpose cable and line protection. Normal use sees minimal temperature rise and no audible noise from the fuse element.
Sustained overload behaviour
Under prolonged overcurrent the fuse element melts to interrupt the circuit before conductors are damaged. The 50kA rating guarantees safe interruption even during severe short-circuit events. Once operated the fuse must be replaced as it is a single-use protective device.
Highlights
- Box of 20 fuses simplifies stock management
- 2 A rating protects low-current circuits reliably
- gG class clears general-purpose overloads cleanly
- 500/690 V rating suits industrial voltage levels
- 50 kA breaking capacity handles severe fault currents
Specifications
| Model | RO15 RT18-32 RT14-20 RT19-25 gF2 |
|---|---|
| Type | Circuit Protectors |
| Selling Unit | Box |
| Amps | 2 |
Questions about this item
How do I install the Ø10×38mm cylindric fuse and what step is often missed?
Insert the 10 mm diameter by 38 mm long fuse into a compatible holder until the end caps seat firmly; the step often missed is verifying the holder is rated for 500/690 V and 50 kA breaking capacity before closing the circuit.
What maintenance or replacement will the 2 A gG fuse need later?
The fuse is a single-use 2 A gG device; after it interrupts a fault it must be replaced with an identical 2 A gG Ø10×38 mm unit — no routine maintenance is required.
What limit appears first when the 2 A gG fuse runs under sustained load?
The 2 A continuous-current rating is the first limit; sustained current above 2 A will cause the gG element to melt and open the circuit.