We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

OEM Industries

OEM Industries GSG RGS4 35A 690V 50KA Cylindric Ceramic fast blow Fuse Bolted joint line protection

SKU CH-Y8N9-0MMDM

A 35 A fast-blow ceramic fuse rated for 690 V and 50 kA breaking capacity with bolted joints for secure line protection

  • TypeCircuit Protectors
  • Amps35
  • 35 A rated current protects circuits from overload
  • 690 V AC voltage rating suits high-voltage industrial systems
  • 50 kA breaking capacity interrupts severe fault currents safely
  • Fast-blow ceramic tube element clears short circuits rapidly
  • Bolted joint terminals provide secure low-resistance connections

Industrial line protection fuse

The OEM Industries GSG RGS4 is a cylindric ceramic fast blow fuse rated at 35 amps for 690 volt AC circuits. It suits maintenance teams and panel builders who need reliable short-circuit protection in industrial power distribution.

Bolted joint and high breaking capacity

The bolted joint ensures a secure, low-resistance connection that resists vibration in generator and electrical supply equipment. A 50 kA breaking capacity at 690 volts lets the device interrupt heavy fault currents without arcing damage.

Simple bolt-in installation

Mounting uses standard bolted terminals so no special tools are required beyond a torque wrench. The main risk is under-torqued bolts creating hot spots, so follow the manufacturer’s torque value and verify contact pressure after the first load cycle.

Highlights

  • 35 A rated current protects circuits from overload
  • 690 V AC voltage rating suits high-voltage industrial systems
  • 50 kA breaking capacity interrupts severe fault currents safely
  • Fast-blow ceramic tube element clears short circuits rapidly
  • Bolted joint terminals provide secure low-resistance connections

Specifications

SeriesGSG RGS4
ModelGSG RGS4
TypeCircuit Protectors
Amps35

Questions about this item

When does the 35 A fuse element need replacement after a fault?

The ceramic tube fuse is a single-use device; once it interrupts a fault the entire unit must be replaced because the element cannot be reset.

What sustained current causes the 63 A aR rating to open first?

The fuse is rated 35 A continuous; currents above that level will cause the element to melt, with the 63 A aR value defining the tested breaking performance at 690 V.

How much heat does the bolted-joint fuse dissipate during all-day operation at 35 A?

At rated current the fuse runs warm but stays within ceramic-body limits; the bolted joints ensure low contact resistance so temperature rise remains moderate.