Nibco, Inc.
Nibco, Inc. 6002 3" x 2-1/2" FTG x C Copper Reducer
Connects 3-inch and 2-1/2-inch copper tubing with an FTG-by-C wrought-copper fitting rated to 317 psi at 100 degrees F and a -20 to 400 degree F range
- TypeDrain Components
- MaterialHAWA
- Reduces pipe diameter with wrot copper construction
- FTG x C connection fits 3 in to 2 1/2 in tube
- Rated 317 psi at 100 degrees F operating pressure
- Withstands temperatures from -20 to 400 degrees F
- Meets ASME/ANSI B 16.22 standard for quality
Copper Reducer Dimensions
The Nibco 6002 is a wrot copper reducer fitting designed to join a 3 inch tube to a 2-1/2 inch tube. It uses an FTG by C connection type and meets ASME/ANSI B16.22 standards for plumbing installations.
Installers and System Constraints
This fitting suits plumbers who need a straight reduction between the two listed tube sizes in copper piping systems. It is not for installers who require a different diameter combination, a press or push-fit connection style, or a fitting rated above 317 psi at 100 degrees F.
Pressure and Temperature Rating
The reducer withstands a maximum pressure of 317 psi at 100 degrees F and operates across a temperature range of -20 degrees to 400 degrees F. This rating determines whether the part matches the design limits of the intended water or heating system.
Highlights
- Reduces pipe diameter with wrot copper construction
- FTG x C connection fits 3 in to 2 1/2 in tube
- Rated 317 psi at 100 degrees F operating pressure
- Withstands temperatures from -20 to 400 degrees F
- Meets ASME/ANSI B 16.22 standard for quality
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Nibco |
| Model | 6002 3x21/2 |
Questions about this item
How do I solder the 3-1/8 in outside diameter end into a 3 in copper tube without overheating the wrot copper?
Clean both surfaces, apply flux, insert the 3-1/8 in fitting end fully into the 3 in tube, heat the joint evenly until solder flows, then wipe excess; avoid prolonged heat above 400 Degrees F to protect the material.
Will the wrot copper reducer need replacement due to corrosion or scaling in a hot water system?
Wrot copper resists corrosion in potable water; inspect joints annually for green patina or leaks, and replace only if pitting or seepage appears at the FTG x C connection.
At what pressure will the reducer reach its 317 psi limit during continuous 100 Degrees F operation?
The 317 psi rating applies at 100 Degrees F; sustained pressure above this value risks joint failure, so install a relief valve set below 317 psi for safety.