Macromatic
Macromatic CAP10AD62 Current Sensing Relay 120VAC SPDT 0.10-10.00A
Monitors AC current from 0.10 to 10.00 A and switches an SPDT relay at 120 VAC with adjustable trip delay
- Adjustable trip point covers 0.10 to 10.00 A for flexible load monitoring
- SPDT contact form switches two circuits with a single relay
- Internal sensor opening simplifies installation without external CTs
- LED status indicator provides immediate visual confirmation of relay state
- 120 V AC control voltage suits standard industrial control panels
Current Sensing Relay 120 V AC
The Macromatic CAP10AD62 monitors AC current from 0.10 to 10.00 A and switches a SPDT relay output rated at 10 A at 240 V AC or 8 A at 28 V DC. It plugs into a standard socket and uses an internal toroidal sensor, so installers do not need to run conductors through an external window. A front-panel LED shows trip status at a glance.
Adjustable trip and delay for steady operation
Trip point and delay are both adjustable from 0.10 to 10.00 A and 0.10 to 10 seconds respectively, letting the relay ignore brief inrush or transient spikes. The internal sensor and fixed hysteresis prevent chatter when load current hovers near the threshold, giving reliable protection for motors, heaters and lighting circuits under continuous duty.
SPDT contact form decides fit
The single-pole double-throw output provides one normally-open and one normally-closed path, which suits control schemes that need both a run and an alarm circuit from one device. Builds that require multiple poles, latching action or a different coil voltage cannot use this relay.
Highlights
- Adjustable trip point covers 0.10 to 10.00 A for flexible load monitoring
- SPDT contact form switches two circuits with a single relay
- Internal sensor opening simplifies installation without external CTs
- LED status indicator provides immediate visual confirmation of relay state
- 120 V AC control voltage suits standard industrial control panels
Specifications
| Brand | MACROMATIC |
|---|
Questions about this item
How much heat does the CAP10AD62 generate when it runs continuously at 10 A on the 240 V AC contacts?
The relay is rated for 10 A at 240 V AC and 8 A at 28 V DC; normal operation within these limits produces only the heat typical of a plug-in relay with an internal core.
What wiring and mounting hardware must I already have to install the CAP10AD62?
You need a standard plug-in relay socket and a terminal strip for the electrical connections; the unit mounts by plugging into the socket.
Will the CAP10AD62 work with my existing 120 V AC control circuit and 28 V DC load?
Yes — the control voltage is 120 V AC and the DC contact rating is 8 A at 28 V, so it matches both your control circuit and your DC load.