LUMICLEANSE UV Germicidal Fixture 38W 254nm 120V 17 1/2in
Ultraviolet germicidal fixture delivers 38 W of 254 nm UV-C light to disinfect up to 300 sq ft in 60 minutes with a 10,000-hour rated life
- Delivers germicidal UV-C exposure at 254 nm wavelength
- 38 W mercury-vapor lamp rated for 10 000 hours of operation
- Treats up to 300 sq ft with selectable 15/30/60-minute cycles
- Surface-mount design includes 96 in power cord for 120 V supply
- Suited for dry locations such as offices, bathrooms and break rooms
UV-C Germicidal Fixture for Dry Indoor Spaces
The LUMICLEANSE fixture emits 254 nm UV-C light at 38 W from a mercury-vapor lamp powered by 120 V. It is built for surface-mount installation in bathrooms, break rooms, hotel rooms, maintenance rooms, offices and service counters that are rated for dry locations only.
Thermal and Power Profile in Normal Use
The unit draws 38 W continuously during a disinfection cycle and includes a 96 in power cord for connection to a standard outlet. Rated lamp life is 10,000 hours, and the fixture contains no filter that would require periodic cleaning or replacement.
Cycle Times Define Coverage per Session
Preset dose cycles deliver 15 minutes for 50 sq ft, 30 minutes for 75 sq ft and 60 minutes for 100 sq ft, with an overall reach up to 300 sq ft. Buyers needing shorter cycles for larger areas or automatic occupancy sensors will not find those functions in this model.
Highlights
- Delivers germicidal UV-C exposure at 254 nm wavelength
- 38 W mercury-vapor lamp rated for 10 000 hours of operation
- Treats up to 300 sq ft with selectable 15/30/60-minute cycles
- Surface-mount design includes 96 in power cord for 120 V supply
- Suited for dry locations such as offices, bathrooms and break rooms
Specifications
| Brand | LUMICLEANSE |
|---|
Questions about this item
How do I mount the fixture and what is the one step installers often miss?
Surface-mount the unit using the supplied hardware, plug the 96 in power cord into a 120 V outlet, then verify the area is unoccupied before starting a cycle — the step most often missed is confirming no people or pets remain in the space during UV-C exposure.
Which component will need replacement first and after how many hours?
The mercury-vapor lamp is the only consumable; it is rated for 10 000 hr of operation, after which UV-C output drops below effective germicidal levels and the lamp must be replaced.
What is the maximum area I can treat in a single cycle before the timer limits me?
The fixture covers up to 300 sq ft, and the longest preset dose cycle is 60 min for 100 sq ft; larger areas require multiple consecutive cycles.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.